Warning: The magic method Gallery_Video::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/gallery-video/video-gallery.php on line 86

Warning: The magic method Hugeit_Slider::__sleep() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 262

Warning: The magic method Hugeit_Slider::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 264
Remote Sensor System | TKK Corporation


Remote Sensor System

Supplies Power and transmits Detected-signals inductively.

Remote Sensor System

Functions

Simultaneously supply operation power to the Detector etc., and transmit detected signal to a controller.

Power Supply

Driving voltage:12V DC or 24V DC

Driving current:5mA … 300mA

Signal transmission

Switching signal
Applicable Detector sensor: Proximity, optoelectronic or magnetic switch
Transmitting signal: 1/2/4/8/15/16 signals
Interface between the controller: NPN or PNP parallel output
Analog signal
Applicable detector sensor: Thermocouple (K / J)

Resistance thermometer (Pt)

Load cell

Transmitting signal: 1/2 signals
Interface between the controller: Current output(4…20mA

Voltage output(0…10V)

System configuration

Switching signal

Switching signal
  • DC-3Wire type: Standard switches can be used for DC-3Wire type
  • DC-2Wire type: Possible to connect with DC2W or mechanical limit switch through resistance.
  • Exclusive proximity switch type: Proximity switch for Remote sensor is used and space-saving.

Analog signal

Analog signal
  • Thermocoupler type : Inductively transmit temperature measuring data from thermocouple, and output in analog value from 4mA to 20mA corresponding to temperature change.
  • Resistance thermometer sensor type : Inductively transmit temperature measuring data from resistance thermometer, and output in analog value 4mA to 20mA corresponding to temperature change.
  • Load cell type : Inductively transmit measuring data from load cell, and output in analog value 4mA to 20mA corresponding to temperature change.
  • Analog sensor type : Supply power to the Analog sensor, inductivelytransmit the output signal and output in analog value from 0 to 10V.

Specification

Switching signal Transmission
DC3 wire detector type PDF FILE
Sensor type(Detector) Number of Signals Operating distance Size Type code Transmitter Output sensor
DC-3 Wire -Standard proximity switch 1 4mm M18 RPT-1804-PU RPE-1804-PU
8mm M30 RPT-3008-PU RPE-3008-PU
4 3mm M18 RPTA-1803-PU RPEA-1803-PU
5mm M30 RPTA-3005-PU RPEA-3005-PU
8 5mm M30 RGPT-3005-V1215-PU RGPE-3005-V1215-PU
8mm 40×40 RGPT-4008-V1220A/B-PU
15mm 80×80 RPTA-8010-PU RPEA-8010-PU
12mm 90×90 RGPT-9012-V2430-PU RGPE-9012-V2430-PU
Sensor type (Detector) Number of Signals Operating distance Size Type code
Remote terminal Transmission head Output head
DC-3 Wire -Standard proximity switch 8 8mm M30 RS8T-222P-S04 RSH8T-030-PU-CP1.0 RSH8E-030-PU
16 8mm M30 RS16T-211P-S04 RSH16T-030-PU-CP1.0 RSH16E-030-PU
DC2 wire detector type PDF FILE
Sensor type (Detector) Number of Signals Operating distance Size Type code
Transmitter Output sensor
DC-2 Wire
-Standard proximity switch
-Exclusive proximity switch/RFD series
1 2mm M12 RPT-1202D-PU RPE-1202-PU
4mm M18 RPT-1804D-PU RPE-1804-PU
8mm M30 RPT-3008D-PU RPE-3008-PU
2 4mm M18 RPT2-1804D-PU RPE2-1804-PU
5mm M30 RPT2-3005D-PU RPE2-3000-PU
4 3mm M18 RPT4-1803D-PU RPE4-1803-PU
5mm M30 RPT4-3005D-PU RPE4-3005-PU
8 3mm M18 RPT8-1803D-PU RPE8-1800-PU
7mm M30 RPT8-3007D-PU RPE8-3000-PU
15 5mm M30 RPT15-3005D-PU RPE15-3000-PU
Sensor type (Detector) Number of Signals Operating distance Size Type code
Remote terminal Transmission head Output head
DC-2 Wire
-Standard proximity
-RFD series
8 8mm M30 RS8T-222P-S04 RSH8T-030-PU-CP1.0 RSH8E-030-PU
16 8mm M30 RS16T-211D-S04 RSH16T-030-PU-CP1.0 RSH16E-030-PU
DC2 wire Exclusive detector type PDF FILE
Sensor type (Detector) Signals Operating distance Size Type code
Transmitter Output sensor
-Exclusive proximity switch/RXD series 1 2mm M12 RXT-1202-PU RXE-1202-PU
2mm M12 RST-1202-PU
5mm M18 RXT-1805-PU RXE-1805-PU
8 5mm M18 RXT8-1805-PU RXE8-1800-PU
10mm M30 RXT8-3010-PU RXE8-3000-PU
Exclusive proximity switch RFD/RXD series PDF FILE
Sensor type (Detector) Operating distance Size Type code Applicable Transmitter
RFD Series : for DC2 wire detector type(with LED) 1.5mm M8 RFD-0801-PU RPT-xxxxD
2mm M12 RFD-1202-PU
5mm M18 RFD-1805-PU RPTx-xxxxD
10mm M30 RFD-3010-PU
RXD Series : for Exclusive detector type(no LED) 1.5mm M8 RXD-0801-PU
2mm M12 RXD-1202-PU RXT-xxxx
5mm M18 RXD-1805-PU RXT8-xxxx
10mm M30 RXD-3010-PU
Terminal Box for Connecting Detector and Transmitter PDF FILE
Type code Note
Standard type -A box for factory automation system is used as the housing. max.4 detectors RPK-2102 DC3 Wire-DC2 wire
RPK-2101 DC3 Wire-DC2 wire
-Protection class; IP 65 max.8 detectors RPK-2103 DC3 Wire-DC2 wire
RFK-3101 RPT8-RXT8
Waterproof type -Orignal “box” which has a round screw lid.
-Protection class; IP 67
max.8 detectors RPK-A098-02 DC3 Wire-DC2 wire
RPK-A098-03 DC3 Wire-DC2 wire
RPK-B148-02 DC3 Wire-DC2 wire
max.15 detectors RPK-B148-03 DC3 Wire-DC2 wire
max.8 detectors RFK-A098-02 RPT8-RXT8
RFK-A098-03 RPT8-RXT8
Connector type -Detectors can be connected to Terminal Box with connecors.
-Transmitter is connected with screwless terminal block.

-Protection class; IP 67

max.4 detectors RPK-4C01 DC3 Wire – DC2 wire
max.8 detectors RPK-8C01 DC3 Wire – DC2 wire
RPK-8C01L RGPT-xxxx
RFK-8C01 RXT8
Accessories PDF FILE
Type code Note
Converting Amplifier -Converts operating voltage from 24V DC to 100V AC then supplies power to AC2 wire detector switch. RGP4T-AC100-KB02A ApplicableTransmitter
RGPT-xxxx
Handy Checker -Indicates Inzone signal and Output signal (8 signal) on LED,and confirms the sensors operate normally. RSCK-200
Analog signal Transmission
Thermocouple PDF FILE
Sensor type measuring range Number of Signals Operating distance Size Type code
Transmitter
Amplifier
Output sensor Head
Thermocouple K 1000 C 1 4mm M18 RTT-1804-K100 RTE-1804E-PU
2 4mm M30 RS02T-018-K1000
300 C 2 4mm M30 RS02T-018-K300
Thermocouple J 300 C 2 4mm M30 RS02T-018-K300 RS02E-018E-PU
Resistance thermometer PDF FILE
Sensor type measuring range Number of Signals Operating distance max. Size Type code Transmitter Output sensor
Resistnace thermometer Pt100 100 C 1 4mm M18 RTT-1804-PT1B10-PU RTE-1804E-PU
200 C RTT-1804-PT1B20-PU
300 C RTT-1804-PT1B30-PU
Load Cell type
Applicable sensor Sensibility Number of Signals Operating distance max. Size Type code Transmitter Output sensor
Compression Load cell 1mV/V 1 4mm M18 RNT-1804-LC10-PU RTE-1804E-PU
1.5mV/V RNT-1804-LC15-PU
2mV/V RNT-1804-LC20-PU
Analog Sensor type PDF FILE
Applicable sensor Output voltage Number of Signals Operating distance max. Size Type code Transmitter Output sensor
Voltage output analog sensor 10V 1 2.5mm M18 RNT-1803-VS10-PU RNE-1803A-PU