DHS series
Rated Input: DC60 – 160V, DC200 – 400V
Rated Output Wattage: 50 – 250W
* When remote ON/OFF is not used, short RC and -VIN.
* When the output voltage adjustment is not used, open the TRM pin respectively.
* When remote sensing is not used, make sure +VOUT and +S are shorted, and that -VOUT and -S are shorted as well.(DHS200/250)
Features
- Compact DC-DC Converter, “BRICK SIZE” which has been standard size for Telecommunication Market
- High efficiency
- High density
- High reliability: not built-in aluminum and tantalum electrolytic capacitor
- Built-in overcurrent, overvoltage and thermal protection circuits
- Built-in remote ON/OFF
Line-up
Output Wattage | Model | Dimensions | Cooling Method |
---|---|---|---|
50W | DHS50A | 58.4×12.7×37.3mm [2.3×0.5×1.47 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |
100W | DHS100A | 58.4×12.7×37.3mm [2.3×0.5×1.47 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |
200W | DHS200A | 58.4×12.7×61.0mm [2.3×0.5×2.4 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |
50W | DHS50B | 58.4×12.7×37.3mm [2.3×0.5×1.47 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |
100W | DHS100B | 58.4×12.7×37.3mm [2.3×0.5×1.47 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |
250W | DHS250B | 58.4×12.7×61.0mm [2.3×0.5×2.4 inches] | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) |