Specifications

Type V7-01-4 V7-02-4 V7-04-4 V7-07-4 V7-15-4 V7-22-4 V7-37-4
Standard applied motor output[kW] 0.1 0.2 0.4 0.75 1.5 2.2 3.7
Output rating Rated capacity[kVA] 0.3 0.57 1.1 1.9 3.0 4.2 6.5
Voltage[V] Three-phase, 200 to 240 V (with AVR function)
Rated current[A] 0.8(0.7) 1.5(1.4) 3.0(2.5) 5.0(4.2) 8.0(7.0) 11.0(10.0) 17.0(16.5)
Rated overload current 150%-1 min or 200%-0.5 s of the rated output current
Rated frequency[Hz] 50・60
Input voltage Number of phases, voltage, frequency Three-phase, 200 to 240 V, 50/60 Hz
Allowable variations of voltage and frequency Voltage: +10 to -15% (unbalance between phases: within 2% (* 10)) Frequency: +5 to -5%
Rated input current (with DCR)[A] 0.57 0.93 1.6 3.0 5.7 8.3 14.0
Rated input current (without DCR)[A] 1.1 1.8 3.1 5.3 9.5 13.2 22.2
Required power supply capacity[kVA] 0.2 0.3 0.6 1.1 2.0 2.9 4.9
Braking Braking torque[%] 150 150 100 100 50 30 30
DC braking Braking start frequency: 0.0 to 60.0 Hz, braking time: 0.0 to 30.0 s, braking level: 0 to 100%
Braking transistor Built-in
Structure/Methods Applicable safety standard UL508C IEC 61800-5-1:2007
Protection structure (IEC60529) IP20 enclosure UL open type
Cooling method Self-cooling Fan cooling
Environment Operating atmosphere Indoor with no exposure to corrosive gases, dust, oil mist (pollution degree 2 (IEC 60664-1:2007)) or direct sunlight
Ambient temperature[℃] Open -10 to 50
Ambient humidity 5 to 95%RH
Altitude 1,000 m or below: No power reduction; 1001 to 1500 m: 0.97, 1501 to 2000 m: 0.95; 2001 to 2500 m: 0.91; 2501 to 3000 m: 0.88
Vibration 3 mm: 2 to 9 Hz or less; 9.8 m/s2: 9 to 20 Hz or less; 2 m/s2: 20 to 55 Hz or less; 1 m/s2: 55 to 200 Hz or less
Storage temperature[℃] -25 to 70
Storage humidity 5 to 95%RH
Mass[kg] 0.6 0.6 0.7 0.8 1.7 1.7 2.5

* The rated output current shown is for a carrier frequency (function code F26) set to 3 kHz or less. Use the current shown in parentheses or less if the carrier frequency is set to 4 kHz or more or if the operating ambient temperature is more than 40℃.

Dimensions 1

Unit[mm]
Motor for power supply Type D[mm] D1[mm] D2[mm]
Three-phase, 200 V, 0.1 kW V7-01-4 80 70 10
Three-phase, 200 V, 0.2 kW V7-02-4 80 70 10
Three-phase, 200 V, 0.4 kW V7-04-4 95 70 25
Three-phase, 200 V, 0.75 kW V7-07-4 120 70 50

Dimensions 2

Unit[mm]
Motor for power supply Type
Three-phase, 200 V, 1.5 kW V7-15-4
Three-phase, 200 V, 2.2 kW V7-22-4

Dimensions 3

Unit[mm]
Motor for power supply Type
Three-phase, 200 V, 3.7 kW V7-37-4