Warning: The magic method Gallery_Video::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/gallery-video/video-gallery.php on line 86

Warning: The magic method Hugeit_Slider::__sleep() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 262

Warning: The magic method Hugeit_Slider::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 264
Valcom VMM6 Series | TKK Corporation


Valcom VMM6 Series

  • Multiple process inputs: 1~5V, ±5V, 4~20mA, and ±20mA
  • High speed sampling at a maximum of 1000 samples per second.
  • Models with analog outputs are multiple output type that enables scaling at any range among 0 to 1 V, 0 to 10 V, 1 to 5 V, and 4 to 20 mA.
  • Alarm setting values can be adjusted easily by the jog lever.
  • LED alternates between red and green, allowing the judgment result to be identified by color.
  • Comparative setting outputs (3 points: H/G/L) included as standard.
  • Various functions included as standard.
    “Start hold”, “Digital zero”, “Peak hold” and “Pattern select” functions included.

Various Functions

Pattern Select Function
This function stores up to eight patterns of scaling data and comparator data, and allows the users to set patterns as desired.
Pattern selection can be controlled either via terminals or via front keys according to the condition data setting. In case of control via terminals, short the terminals between P.SEL1 to 3 and COM or make them equipotential to enable pattern switching from P-1 up to P-8. In case of control via front keys, hold down the increment key for approx. 3 seconds to switch patterns.

Start Hold Function
This function holds the display at the desired timing. Either A or B type can be set according to the condition data.
A type is a free run mode. In the free run condition, shorting S/H and COM terminals or making them equipotential will hold the displayed value and the comparison judgment value.
B type is a one-shot mode. In the hold condition, shorting S/H and COM terminals or making them equipotential will output the displayed value and the comparison judgment value once.

Peak Hold Function
This function holds any of the maximum (peak) value, the minimum (valley) value, and the difference between the maximum and the minimum (peak – valley) and outputs the value held. (The value to be held is switched according to the condition data.)
Shorting S/H and COM terminals or making them equipotential will turn ON the peak hold function.

Digital Zero Function (Display reset function)
This function forcibly zeros the displayed value. It is useful when subtracting tare weight during load measurement with load cells connected.
Display reset (Digital zero) function ON/OFF can be controlled via terminals or via front keys according to the condition data setting.
In case of control via terminals, shorting the terminals between DZ and COM or make them equipotential to turn ON the display reset function. In case of control via front keys, hold down the shift key for approx. 3 seconds to turn ON the function.

Specification

Display Main display Red/Green 7 segments LED display(Character height: Approx. 20mm)
Sub display Red 7 segments LED display(Character height: Approx. 6mm)
Display Range -9999~9999
Use Temperature Range 0~50°C
Use Humidity Range 35~85%RH
Storage Temperature Range -10~70°C
Storage Humidity Range 60%RH or less
Power AC power: AC100~240V±10%
DC power: DC12~48V±10%
Power Consumption Maximun rating Approx. 8VA(AC100V)
Maximun rating Approx. 7W(DC24V)
Dielectric Strength AC power: Power-Input-Output AC1500V 1 minute
DC power: Power-Input-Output DC500V 1 minute
(Common) Input-Output DC500V 1 minute
Output-Output DC500V 1 minute
Case-Power, Input, Output AC1500V 1 minute
Insulation Resistance 100MΩ min. at 500V DC between above terminals
Dimensions 96mm(W)×48mm(H)×99.5mm(D)
Weight Approx. 450g
Accessories Operation manual (1 copy) Unit labels Case fixing band×2 Cover between terminals for 6-pin terminal block×3

Process signal input specifications

Measuring Range Range 1V: 1~5V
Range 2V: ±5V
Range 2A: 4~20mA
Range 3A: ±20mA
Display Offset: ±9999 Scaling: ±9999
Input Impedance Range 1V, Range 2V: Approx. 1MΩ
Range 2A, Range 3A: Approx. 10Ω
Maximum Safe Input Range 1V, Range 2V: ±100V
Range 2A, Range 3A: ±50mA
Accuracy Range 1V, Range 2V: ±(0.03% of rdg +2digit)(23°C±5°C 35~85%)
Range 2A, Range 3A: ±(0.1% of rdg +3digit)(23°C±5°C 35~85%)
Sensor Power Supply DC12V±10% 50mA or DC24V±10% 25mA
Sampling speed Approx. 1000 times/sec.

Comparison output specifications

Trigger Value Range -9999~9999
Hysteresis Can be set in the range of 1 to 999 digits for each value.
Comparison Operation Depends on the sampling rate.
Comparison Relay Relay Contact Output Maximun10ms
Number of Contacts Relay contact ×3
Contact Rating AC250V 2A(Resistive load)
DC30V 2A(Resistive load)
Comparison Condition
Supply voltage range:
Displayed value>HI trigger value
Judgment: HI
Supply voltage range:
LO trigger value&leDisplayed value&leHI trigger value
Judgment: GO
Supply voltage range:
LO trigger value>Displayed value
Judgment: LO
Photo-coupler Output Number of Output Photo-coupler ×3
Photo-coupler Output 200µs
Contact Rating DC30V 20mA (Resistive load)
Supply voltage range:
Displayed value>HI trigger value
HI
Supply voltage range:
HI trigger value≥Displayed value≥LO trigger value
GO
Supply voltage range:
LO trigger value>Displayed value
LO

Analog output specifications

Load Resistance 0~1V, 0~10V, 1~5V: 10kΩ or more
4~20mA: 550Ω or less
Accuracy ±(0.5% of FS)
Ripple 0~1V, 0~10V, 1~5V: ±50mVp-p
4~20mA: ±25mVp-p
Conversion Method PWM conversion method
Resolution Equivalent to max. 14 bits (depends on output display setting)
Scaling Digital scaling
Response Time Approx. 0.5 sec.

BCD output specifications

Output Type Open collector output NPN type
Output Logic Selectable (PC logic not selectable)
Rated Output DC30V MAX.
10mA MAX.