Warning: The magic method Gallery_Video::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/gallery-video/video-gallery.php on line 86

Warning: The magic method Hugeit_Slider::__sleep() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 262

Warning: The magic method Hugeit_Slider::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 264
Valcom FIT®/5 Series | TKK Corporation


Valcom FIT®/5 Series

Digital Load Cell for Dynamic Weighing

  • All stainless steel hermetic seal
  • IP Rating: IP68 ■CE mark
  • Overload protection mechanism (Fracture load: 1000%)
  • Trigger functions (external/level trigger)
  • Parameter setting and dynamic quantitative analysis by PC software[Option]
  • Filling/mixing control functions
  • Limit switch × 4
  • Cable sold separately.

Specification 1 (Load transmitter)

Model FIT®/5…
Accuracy Class according to OIML R60 C3
Max. Capacity(Emax) kg 5 10
Min. Load Cell Verification Interval(Vmin) g 0.5 1
Min. Application Range for 3000d kg 1.5 3
Max. Platform Size mm 400×400
Max. Number of Load Cell Verification Intervals(nLC) 3,000
Temperature Effect on Sensitivity(TKC) (*1)(*2)
in Temperature Range 0°C…+40°C
%(Sensitivity)/10k ±0.0250
Temperature Effect on Zero Signal(TKSO) (*2) %(Sensitivity)/10k ±0.0200
Relative Umkehrspanne(dhy) (*1)(*2) % ±0.0166
Non Linearity (*1)(*2) % ±0.0166
Creep(dCR)over 30 min % ±0.0166
Eccentric Loading Error acc. to OIML R76 % ±0.0233
Service Load (EU); Max. 120 mm Eccentricity %(Max. capacity) 150
Safe Load Limit (EL); Max. 20 mm Eccentricity %(Max. capacity) 1,000
Permissible Dyn. Load(Fsrel)Max. 50 mm Eccentricity %(Max. capacity) 70
Deflection at Max. Capacity(snom) mm <0.2
Power Supply:
Supply Voltage UB1(DC) V +10~+30
Power Consumption W &le2
Switch-on Current A 0.2
Resolution of Meas. Signal(1 Hz-Filter) Bit 20
Sampling speed
(Output format and baud rate)
1/s 4~1,200
Adjustable Cut-off Frequency of the Digital Filters
Filteremode 0 Hz 200~0.25
Filteremode 1 (Response Time 62…365ms) Hz 18~2.5
Baud Rate (RS-232-,RS-485-interface) Baud 1,200:2,400:4,800:9,600:
19,200:38,400:57,600:115,200
Max. Number of Bus Members 90
CANopen Interface Standard CiA DS301
Baud Rate Baud 10,000~1,000,000
DeviceNet Interface Release 2.00DVA
Baud Rate Baud 125,000~500,000
Max. Cable Length(CANOpen,DeviceNet) m &le5,000(10k Baud)
&le100(500k Baud)
&le25(1M Baud)
Diagnostic Channel,RS-485-2-wire(Version E)
Baud Rate Baud 38,400
Max. Cable Length / Max. Number of Bus Members m/ 500/90
Asynchronous Serial Interface (Female Device Connector 1)
RS-485,4 Leiter,Max. Cable Length m 500
RS-232 Max. Cable Length m 15
Trigger Input (Female Device Connector 1)
Permissible Input Voltage V 0~+12
Low-level V <1
High-level V >4
Input Resistance 10
Control Inputs (Optional, Female Device Connector 2) Isolated reference potential GND2
Permissible Input Voltage V 0~+30
Low-level V <6
High-level V >10
High-level Input Resistance >3
Control Inputs (Optional, Female Device Connector 2) Isolated reference potential GND2
External Supply Voltage UB2 V +11~+30
Max. Current of One Output A <0.5
Accumulated Current of All Outputs A <1.0
High-level V <1
Nominal Temperature Range(BT) °C -10~+40
Operating Temperature Range(Btu) °C -10~+50
Storage Temperature Range(Bti) °C -25~+75
EMC-requirements EN 45501, OIML R76
EN 61326-1, Tab. 4, equipment of class B
EN61326 A1, Tab. A1, equipment in industrial areas
Degree of Protection acc.to EN 60529 IP68
Female Device Connector Fa.Lumberg, 8 pin, Female
Material: Housing Stainless steel
Weight,Approx. kg 2
  • (*1) Individual characteristics values may exceed the above specification in some cases. Non Linearity, maximum combined error due to hysteresis, and impact of temperature on sensitivity meet the requirements defined by OIML R60PLC=1
  • (*2) All values specified based on the output values with the maximum capacity.

List of standard types

Housing Interfaces
RS-232 RS-485(4wire) CANOpen DeviceNet
5 1-FIT/5SC30/10KG

List of expansion (E) types

All of the following types are provided with filling control function and limit switch as options.

Housing Interfaces
RS-232 RS-485(4wire) CANOpen DeviceNet
5 1-FIT/5EA30/10KG 1-FIT/5EB30/5KG
1-FIT/5EB30/10KG
1-FIT/5EC30/5KG
1-FIT/5EC30/10KG
1-FIT/5ED30/5KG