Digital Load Cell for Dynamic Weighing
- All stainless steel hermetic seal
- IP Rating: IP68 ■CE mark
- Overload protection mechanism (Fracture load: 1000%)
- Trigger functions (external/level trigger)
- Parameter setting and dynamic quantitative analysis by PC software[Option]
- Filling/mixing control functions
- Limit switch × 4
- Cable sold separately.
Specification 1 (Load transmitter)
Model | FIT®/5… | ||
---|---|---|---|
Accuracy Class according to OIML R60 | C3 | ||
Max. Capacity(Emax) | kg | 5 | 10 |
Min. Load Cell Verification Interval(Vmin) | g | 0.5 | 1 |
Min. Application Range for 3000d | kg | 1.5 | 3 |
Max. Platform Size | mm | 400×400 | |
Max. Number of Load Cell Verification Intervals(nLC) | 3,000 | ||
Temperature Effect on Sensitivity(TKC) (*1)(*2) in Temperature Range 0°C…+40°C |
%(Sensitivity)/10k | ±0.0250 | |
Temperature Effect on Zero Signal(TKSO) (*2) | %(Sensitivity)/10k | ±0.0200 | |
Relative Umkehrspanne(dhy) (*1)(*2) | % | ±0.0166 | |
Non Linearity (*1)(*2) | % | ±0.0166 | |
Creep(dCR)over 30 min | % | ±0.0166 | |
Eccentric Loading Error acc. to OIML R76 | % | ±0.0233 | |
Service Load (EU); Max. 120 mm Eccentricity | %(Max. capacity) | 150 | |
Safe Load Limit (EL); Max. 20 mm Eccentricity | %(Max. capacity) | 1,000 | |
Permissible Dyn. Load(Fsrel)Max. 50 mm Eccentricity | %(Max. capacity) | 70 | |
Deflection at Max. Capacity(snom) | mm | <0.2 | |
Power Supply: | |||
Supply Voltage UB1(DC) | V | +10~+30 | |
Power Consumption | W | &le2 | |
Switch-on Current | A | 0.2 | |
Resolution of Meas. Signal(1 Hz-Filter) | Bit | 20 | |
Sampling speed (Output format and baud rate) |
1/s | 4~1,200 | |
Adjustable Cut-off Frequency of the Digital Filters | |||
Filteremode 0 | Hz | 200~0.25 | |
Filteremode 1 (Response Time 62…365ms) | Hz | 18~2.5 | |
Baud Rate (RS-232-,RS-485-interface) | Baud | 1,200:2,400:4,800:9,600: 19,200:38,400:57,600:115,200 |
|
Max. Number of Bus Members | 90 | ||
CANopen Interface | Standard CiA DS301 | ||
Baud Rate | Baud | 10,000~1,000,000 | |
DeviceNet Interface | Release 2.00DVA | ||
Baud Rate | Baud | 125,000~500,000 | |
Max. Cable Length(CANOpen,DeviceNet) | m | &le5,000(10k Baud) | |
&le100(500k Baud) | |||
&le25(1M Baud) | |||
Diagnostic Channel,RS-485-2-wire(Version E) | |||
Baud Rate | Baud | 38,400 | |
Max. Cable Length / Max. Number of Bus Members | m/ | 500/90 | |
Asynchronous Serial Interface (Female Device Connector 1) | |||
RS-485,4 Leiter,Max. Cable Length | m | 500 | |
RS-232 Max. Cable Length | m | 15 | |
Trigger Input (Female Device Connector 1) | |||
Permissible Input Voltage | V | 0~+12 | |
Low-level | V | <1 | |
High-level | V | >4 | |
Input Resistance | kΩ | 10 | |
Control Inputs (Optional, Female Device Connector 2) | Isolated reference potential GND2 | ||
Permissible Input Voltage | V | 0~+30 | |
Low-level | V | <6 | |
High-level | V | >10 | |
High-level Input Resistance | kΩ | >3 | |
Control Inputs (Optional, Female Device Connector 2) | Isolated reference potential GND2 | ||
External Supply Voltage UB2 | V | +11~+30 | |
Max. Current of One Output | A | <0.5 | |
Accumulated Current of All Outputs | A | <1.0 | |
High-level | V | <1 | |
Nominal Temperature Range(BT) | °C | -10~+40 | |
Operating Temperature Range(Btu) | °C | -10~+50 | |
Storage Temperature Range(Bti) | °C | -25~+75 | |
EMC-requirements | EN 45501, OIML R76 | ||
EN 61326-1, Tab. 4, equipment of class B | |||
EN61326 A1, Tab. A1, equipment in industrial areas | |||
Degree of Protection acc.to EN 60529 | IP68 | ||
Female Device Connector | Fa.Lumberg, 8 pin, Female | ||
Material: Housing | Stainless steel | ||
Weight,Approx. | kg | 2 |
- (*1) Individual characteristics values may exceed the above specification in some cases. Non Linearity, maximum combined error due to hysteresis, and impact of temperature on sensitivity meet the requirements defined by OIML R60PLC=1
- (*2) All values specified based on the output values with the maximum capacity.
List of standard types
Housing | Interfaces | |||
---|---|---|---|---|
RS-232 | RS-485(4wire) | CANOpen | DeviceNet | |
5 | – | – | 1-FIT/5SC30/10KG | – |
List of expansion (E) types
All of the following types are provided with filling control function and limit switch as options.
Housing | Interfaces | |||
---|---|---|---|---|
RS-232 | RS-485(4wire) | CANOpen | DeviceNet | |
5 | 1-FIT/5EA30/10KG | 1-FIT/5EB30/5KG 1-FIT/5EB30/10KG |
1-FIT/5EC30/5KG 1-FIT/5EC30/10KG |
1-FIT/5ED30/5KG 1-FIT/5ED30/10KG |