Valcom VLC-024A Series
[Make to order]
Flat type Load Cell
- Compact and flat type easy to be attached to shafts or cylinders.
- Low cost type
Specification
Rated Output(R.O.) | 1mV/V±0.1mV/V |
---|---|
Non Linearity | ±0.5%R.C. |
Hysteresis | ±0.5%R.C. |
Repeatability | ±0.3%R.C. |
Zero Balance | ±0.1mV/V |
Temperature Effect on Zero Balance | ±0.1%R.C./10°C |
Temperature Effect on Load | ±0.1%R.C./10°C |
Safe Overload Rating | 150%R.C. |
Compensated Temperature Range | -10~60°C(No condensation or freezing) |
Safe Temperature Range | -10~60°C(No condensation or freezing) |
Input Terminal Resistance | 420Ω±50Ω |
Output Terminal Resistance | 350Ω±5Ω |
Excitation;Recommended | 5V or less |
Excitation;Maximum | 10V |
Insulation Resistance | 1000MΩ or more (DC 50V) |
IP Rating | Equivalent to IP54 (Note 1) |
Cable | φ5-4-core shielded robot cable 5m, directly-connected |
- *R.C.: Rated Capacity
- (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.
Model Selection
Model | Rated Capacity(R.C.) | Deflection at R.C. | Weight |
---|---|---|---|
VLC-10KN024A | 10kN | Approx. 0.05mm | Approx. 1kg |
VLC-20KN024A | 20kN | ||
VLC-50KN024A | 50kN | ||
VLC-100KN024A | 100kN |
*Weight includes cable.