Valcom VLTT Series
Floor Scale type Load Cell
- Ultralow profile design of 31 mm in height.
- Amplifier built-in type also available
- Selectable between transmitter and transducer.
Specification 1 (Load transmitter)
Safe Overload Rating | 150%R.C. |
---|---|
Accuracy | ±0.3%R.C.(Non Linearity, Hysteresis, Repeatability included)以内 |
Analog output | 4~20mA |
Power [Consumption current] | DC24V±10% [Approx. 20mA] |
Load Resistance | 500Ω or less |
Compensated Temperature Range | 0~50°C(No condensation or freezing) |
Safe Temperature Range | 0~60°C(No condensation or freezing) |
Temperature Effect | ±1%R.C./10°C |
Casing Material | SUS304 |
Base Plate Material | □140~200: Aluminum □250~500: SPCC (Chromate plating) |
Cable | 2-core shielded cable Flame-retardant, oilproof vinyl sheath |
Specification 2 (Load transducer)
Safe Overload Rating | 150%R.C. |
---|---|
Accuracy | ±0.3%R.C.(Non Linearity, Hysteresis, Repeatability included)以内 |
Rated Output(R.O.) | 2mV/V±1% |
Excitation;Recommended | 10V DC |
Excitation;Maximum | 30V DC |
Compensated Temperature Range | -10~50°C(No condensation or freezing) |
Safe Temperature Range | -10~60°C(No condensation or freezing) |
Temperature Effect | ±1%R.C./10°C |
Casing Material | SUS304 |
Base Plate Material | □140~200: Aluminum □250~500: SPCC (Chromate plating) |
Cable | 4-core shielded cable Flame-retardant, oilproof vinyl sheath |
*R.C.: Rated Capacity