Valcom VLTT Series | TKK Corporation


Valcom VLTT Series

Floor Scale type Load Cell

  • Ultralow profile design of 31 mm in height.
  • Amplifier built-in type also available
  • Selectable between transmitter and transducer.

Specification 1 (Load transmitter)

Safe Overload Rating 150%R.C.
Accuracy ±0.3%R.C.(Non Linearity, Hysteresis, Repeatability included)以内
Analog output 4~20mA
Power [Consumption current] DC24V±10% [Approx. 20mA]
Load Resistance 500Ω or less
Compensated Temperature Range 0~50°C(No condensation or freezing)
Safe Temperature Range 0~60°C(No condensation or freezing)
Temperature Effect ±1%R.C./10°C
Casing Material SUS304
Base Plate Material 140~200: Aluminum
250~500: SPCC (Chromate plating)
Cable 2-core shielded cable
Flame-retardant, oilproof vinyl sheath

Specification 2 (Load transducer)

Safe Overload Rating 150%R.C.
Accuracy ±0.3%R.C.(Non Linearity, Hysteresis, Repeatability included)以内
Rated Output(R.O.) 2mV/V±1%
Excitation;Recommended 10V DC
Excitation;Maximum 30V DC
Compensated Temperature Range -10~50°C(No condensation or freezing)
Safe Temperature Range -10~60°C(No condensation or freezing)
Temperature Effect ±1%R.C./10°C
Casing Material SUS304
Base Plate Material 140~200: Aluminum
250~500: SPCC (Chromate plating)
Cable 4-core shielded cable
Flame-retardant, oilproof vinyl sheath

*R.C.: Rated Capacity

External dimensions (Unit:mm)