Valcom VLTT Series (Water proof) | TKK Corporation


Valcom VLTT Series (Water proof)

Floor Scale type Load Cell (Water proof)

  • Waterproof rating equivalent to IP×7
  • Waterproof, ultralow profile design of 31 mm in height.

Specification 1 (Load transmitter)

Safe Overload Rating 150%R.C.
Accuracy ±0.3%R.C.(Non Linearity, Hysteresis, Repeatability included)以内
Analog output 4~20mA(External AMP-BOX)
Power [Consumption current] DC24V±10% [Approx. 20mA]
Load Resistance 500Ω or less (DC24V)
Compensated Temperature Range 0~50°C(No condensation or freezing)
Safe Temperature Range 0~60°C(No condensation or freezing)
Temperature Effect ±1%R.C./10°C
Casing Material SUS304
Base Plate Material SUS
Cable PVC coated 3-core shielded cable(White/Red/Black/Sielded)
UL-compliant
With 4-pin relay connector (TAJIMI) 3m

*R.C.: Rated Capacity

External dimensions (Unit:mm)