Valcom VPW18C3/H1 Series
High Load-resistant Single Point type Load Cell
- Extremely high overload limit (Fracture load: 1000%, mechanical stopper included)
- Good environmental resistance
- Highly resistant against lateral load and bending stress
Specification
Rated Output(R.O.) | 0.900~1.100mV/V |
---|---|
Non Linearity | ±0.0166%R.C. |
Hysteresis | ±0.0166%R.C. |
Zero Balance | -0.200~0.200mV/V |
Temperature Effect on Zero Balance | ±0.0140%R.C./10°C |
Temperature Effect on Load | 20~40°C: ±0.0175%R.C./10°C -10~20°C: ±0.0117%R.C./10°C |
Safe Overload Rating | 800%R.C. |
Compensated Temperature Range | -10~40°C(No condensation or freezing) |
Safe Temperature Range | -10~50°C(No condensation or freezing) |
Input Terminal Resistance | 350.0~500.0Ω |
Output Terminal Resistance | 350.0~500.0Ω |
Excitation;Recommended | 5V |
Excitation Range | 1~12V |
Insulation Resistance | 1000MΩ(DC100V) |
IP Rating | Equivalent to IP66 (Note 1) |
Cable | 6-core cable 3m |
- *R.C.: Rated Capacity
- Creep 30min.:±0.0166%R.C.
- (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.
Model Selection
Model | Rated Capacity(R.C.) | Maximum Load Area | Ultimate Overload Rating | Deflection at R.C. | Weight |
---|---|---|---|---|---|
VPW18C3/H1-5kg | 5kg(49.03N) | 400×400mm | 1000%R.C. | Approx. 0.15mm | Approx. 3kg |
VPW18C3/H1-10kg | 10kg(98.07N) | ||||
VPW18C3/H1-20kg | 20kg(196.1N) | ||||
VPW18C3/H1-50kg | 50kg(490.3N) | 600×500mm | |||
VPW18C3/H1-75kg | 75kg(735.5N) |
*Weight includes cable.