Valcom VPW6DC3 Series
Single Point type Load Cell
- Ultrahigh accuracy
- Compact
- Good environmental resistance
- Wide weighing range
Specification
Rated Output(R.O.) | 2.0±0.2mV/V |
---|---|
Non Linearity | ±0.0166%R.C. |
Hysteresis | ±0.0166%R.C. |
Zero Balance | ±0.1mV/V |
Temperature Effect on Load | 20~40°C: ±0.0175%R.C./10°C -10~20°C: ±0.0117%R.C./10°C |
Safe Overload Rating | 150%R.C. |
Safe Side Load Level | 300%R.C. |
Compensated Temperature Range | -10~40°C(No condensation or freezing) |
Safe Temperature Range | -10~50°C(No condensation or freezing) |
Input Terminal Resistance | 380±38Ω |
Output Terminal Resistance | 380±38Ω |
Excitation;Recommended | 5V |
Excitation Range | 12V |
Insulation Resistance | 2000MΩ |
IP Rating | Equivalent to IP65 (Note 1) |
Cable | 4-core shielded cable 0.35m |
- *R.C.: Rated Capacity
- Creep 30min.:±0.0245R.C. Eccentric error±0.0233%R.C.
- (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.
Model Selection
Model | Rated Capacity(R.C.) | Temperature Effect on Zero Balance | Maximum Load Area | Deflection at R.C. | Weight |
---|---|---|---|---|---|
VPW6DC3-3kg | 3kg(29.42N) | ±0.0233%R.C./10°C | 300×300mm | Approx. 0.4mm | Approx. 160g |
VPW6DC3-5kg | 5kg(49.03N) | ±0.0280%R.C./10°C | |||
VPW6DC3-10kg | 10kg(98.07N) | ±0.0280%R.C./10°C | |||
VPW6DC3-15kg | 15kg(147.1N) | ±0.0186%R.C./10°C | |||
VPW6DC3-20kg | 20kg(196.1N) | ±0.0350%R.C./10°C | |||
VPW6DC3-30kg | 30kg(294.2N) | ±0.0233%R.C./10°C | |||
VPW6DC3-40kg | 40kg(392.3N) | ±0.0350%R.C./10°C |
*Weight includes cable.