Valcom VS2M Series
[Make to order]
S type Load Cell(Overload Protection)
- Overload protection mechanism included
- Ultimate overload rating: 300 to 900%R.C.
- High accuracy and compact
- For tensile and compressive loads
Specification
Rated Output(R.O.) | 2mV/V±0.25% |
---|---|
Non Linearity | ±0.02%R.C. |
Hysteresis | ±0.02%R.C. |
Effect of Rated Output | ±0.02%R.C. |
Effect on the bending moment (Rated power is 10% of lateral force.) |
±0.02%R.C. |
Zero Balance | ±5%R.O. |
Relative sensitivity difference in power compression / tension |
±0.1%R.O. |
Temperature Effect on Zero Balance | ±0.02%R.C./10°C |
Temperature Effect on Load | ±0.02%R.C./10°C |
Input Terminal Resistance | 345Ω or more |
Output Terminal Resistance | 350Ω±50Ω |
Excitation;Recommended | 5V or less |
Safe Excitation | 0.5~12V |
Insulation Resistance | 2GΩ or more |
Rated Temperature Range | +10~+45°C |
Operating Temperature Range | -10~+70°C |
Storage Temperature Range | -10~+85°C |
Safe Load Level | 150%R.C. |
Service Load | 1000%R.C. |
Safe Load Limit | 1000%R.C. |
Static Lateral Limit Force | 100%R.C. |
Permissible Vibration Amplitude to DIN 50100 | 140% |
Mass(Cable included) | 0.5kg(Approximation) |
IP Rating | Equivalent to IP67 (Note 1) |
Cable | 6-core cable 6m |
- *R.C.: Rated Capacity
- Creep 30min.: ±0.02%R.C.
- (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.
Model Selection
Model | Rated Capacity(R.C.) | Critical Torque | Bending Moment Limit | Deflection at R.C. | Natural Frequency of the Membrane |
---|---|---|---|---|---|
VS2M-10N | 10N | 4N・m | 6N・m | 0.27mm | 94.4Hz |
VS2M-20N | 20N | 8N・m | 25N・m | 0.21mm | 146Hz |
VS2M-50N | 50N | 25N・m | 34N・m | 0.18mm | 243Hz |
VS2M-100N | 100N | 28N・m | 50N・m | 0.15mm | 358Hz |
VS2M-200N | 200N | 28N・m | 71N・m | 0.13mm | 475Hz |
VSM2-500N | 500N | 28N・m | 95N・m | 0.12mm | 582Hz |
VS2M-1000N | 1000N | 28N・m | 125N・m | 0.13mm | 618Hz |