Valcom VESIM T series | TKK Corporation


Valcom VESIM□□T Series

  • Suitable for location with abrupt pressure fluctuation thanks to the diaphragm cover.
  • High environmental resistance(Wide temperature compensation range / IPx7 rating)
  • Quick delivery and low price
Measured medium Water, oil, gases or other media that will not corrode SUS304.
Pressure type Positive pressure can be measured.
Measured Range Rated capacity: 1~50MPa
Output type 4~20mA(2 wire system)

Specification

Non Linearity ±0.5%R.C. or less
Hysteresis ±0.5%R.C. or less
Total Accuracy ±3.0%R.C. or less (-10~55°C)
Compensated Temperature Range
(Temperature of medium to be measured)
-10~55°C
Safe Temperature Range
(Temperature of medium to be measured)
-10~55°C(0~95%R.H. No condensation or freezing)
Response 10msec. or less
Safe Load Resistance 11.5V: 150Ω MAX. / 24V: 500Ω MAX.
Safe Overload Rating 150%R.C.
Wetted Part Material 1~5MPa: SUS304+Zirconia+SUS316L
10~50MPa: SUS304+Zirconia
Insulation Resistance 10MΩ or more (DC50V)
Connection Screw G3/8
Fastening Torque 68.6N・m or less
Protection Equivalent to IP×5
Power [Consumption current] DC12V, DC24V(10~26.5V)
Weight Approx. 300g
Accessories Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy) P-14 1A(×1)
Cable inlet port seal kit
Packing for cable up to 8 mm in O.D.(×1)
Packing for cable up to 10 mm in O.D.(×1)
Washer×1