Valcom VPRF Series | TKK Corporation


Valcom VPRF Series

  • Suitable for measurement of viscous media since the flush type (no feed port) wetted part is hardly clogged up.
  • Wetted part constructed integral with diaphragm does not use any sealed liquid, offering durability, reliability and long life.
  • Abundant analog output available.
    [4~20mA(2 wire system, 4 wire system), 1~5V, 0~5V, 0~10V]
Measured medium Water, oil, gases or other media that will not corrode SUS630.
Pressure type Positive and compound pressures can be measured.
Measured Range Can be specified within the range of 1 MPa to 50 MPa of rated capacity (Calibration: 0.5 MPa to 50 MPa).
Specify more than 50% of rated capacity as the calibration range.
Output type Specify among 4 to 20 mA (2 wire system, 4 wire system), 1 to 5 V, 0 to 5 V, and 0 to 10 V.

Specification

Non Linearity ±0.5%R.C.
Hysteresis ±0.5%R.C.
Compensated Temperature Range
(Temperature of medium to be measured)
-10~50°C(No condensation or freezing)
Safe Temperature Range
(Temperature of medium to be measured)
-10~75°C(No condensation or freezing)
Temperature Effect on Zero Balance ±0.8%R.C./10°C
Temperature Effect on Load ±0.8%R.C./10°C
Safe Overload Rating 150%R.C.
Ultimate Overload Rating 200%R.C.
Insulation Resistance 100MΩ or more (DC50V)
Pressure Port Material SUS630 or 15-5PH (Precipitation hardening stainless steels) (*1)
Connection Screw G3/8
Fastening Torque 10~20N・m
Fastening Torque;Maximum 30N・m
Power Selectable: 4 DC24V(±10%), 5 DC12V(±10%)
*Only 24V DC available when analog output is A5 .
Cable 4- or 2-core shielded (oilproof) cable 2m Standardφ6mm
Weight Approx. 300g(Cable not included)
Accessories Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy)
Aluminum packing(×1)(Copper packing × 1 for 50 MPa model only)