Valcom HSMC2 Series
- 2 setting outputs + 4 to 20 mA(with analog output scaling function)
- Quick zero-adjustment, tracking zero adjustment, loop check and moving average are included as standard.
- Safe and reliable construction with break-proof diaphragm
- Safe and reliable construction with no sealed liquid.
Standard feature
- Damping ●Loop check function ●FIX zero
- Quick zero-adjustment ●Maximum/Minimum display
- Various functions such as output burnout at error.
Measured medium | Alcohols, milk beverage, seasoning, pure water, chemical or other media. (These vary according to sensor materials) |
---|---|
Pressure type | Positive and negative pressures can be measured. |
Pressure range | Can be specified within the range of 50 kPa to 3 MPa (Calibration:25kPa~3MPa) of rated capacity. |
Output type | 4~20mA(4 wire system) 2-point photo-Mos relay output. Specify more than 50% of rated capacity as the calibration range. |
Specification 1 (Sensor assembly)
Sensor Connection | ISO Ferrule, VARIVENT®, ISO Cap nut, Screw mount, Other special orders |
---|---|
Rated Capacity(R.C.) | 50, 100, 200, 300, 500, 1000kPa, 3MPa |
Material | Sensor: SUS316L / Hastelloy C276 / SUS329J4L |
Finish(Sensor Part) | Electro-Chemical Buffing |
Safe Overload Rating | 400%R.C. (Rated capacity 3MPa: 150%R.C.) |
Destruction Point | 1000%R.C. (Rated capacity 3MPa: 300%R.C.) |
Specification 2 (Amplifier + Sensor assembly)
Non Linearity | ±0.5%R.C. |
---|---|
Hysteresis | ±0.5%R.C. |
Compensated Temperature Range (Wetted part) | -5~150°C |
Safe Temperature Range (Wetted part) | -5~150°C |
Temperature Effect on Zero Balance | ±0.5%R.C./10°C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10°C (Rating: 50, 100, 200kPa) | |
Temperature Effect on Load | ±0.5%R.C./10°C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10°C (Rating: 50, 100, 200kPa) | |
Ambient Temperature and Humidity | Temperature:0~50°C(No freezing), Humidity:0~90%RH(No condensation) |
Material | Aluminum die-casting(Case material) Acrylic(Front) SUS304(Radiating fin) |
IP Rating | Equivalent to IP65 |
Mass | Standard: Approx. 960g (A sensor assembly is included. / In the case of ISO ferrule 2S) |
Accessories | Operation manual (1 copy), Test report (1 copy), 1 of connector for a power supply input 1 of connector for a setting output at an analog. (*1) |
(*1) For the ferrule type, zero adjustment is to be made after the clamp is tightened.