Valcom VPB series
- Dedicated to fillers – From chemical cleaning, steam sterilization up to beverage filling.
- Safe and reliable construction with break-proof diaphragm
- Safe and reliable construction with no sealed liquid.
Measured medium | Beer, beverage or other media that will not corrode SUS630. |
---|---|
Pressure type | Positive pressure can be measured. |
Pressure range | Calibration:0~343kPa |
Output type | 4~20mA(2 wire system) |
Specification 1 (Sensor assembly)
Rated Capacity(R.C.) | 500kPa |
Safe Overload Rating | 400%R.C. |
Non Linearity | ±0.8%R.C. |
Hysteresis | ±0.5%R.C. |
Compensated Temperature Range | -5~150°C |
Safe Temperature Range | -5~150°C |
Temperature Effect on Zero Balance | ±0.7%R.C./10°C |
Temperature Effect on Load | ±0.7%R.C./10°C |
Material | SUS630 (Pressure port) |
IP Rating | Equivalent to IP65 |
Weight | Approx. 450g (Sensor + Cable only) |
Accessories | Operation manual (1 copy)(Specify English or Japanese.) Test report (1 copy), Dedicated O-ring |
Specification 2 (Amplifier)
Analog output | 4~20mA(2 wire system) (Safe load resistance:500Ωmax.) |
---|---|
Ambient Temperature and Humidity | Temperature:0~70°C(No freezing) Humidity:0~90%RH(No condensation) |
Power | DC24V±10% |
Material | SUS304(Case material) |
Option | Amplifier case fixation metal fittings |