Anywire DB Master Unit – AFJW01
The high-speed ministry wiring to high-speed PLC.
It is possible to connect directly with new satellite JW made of [sha-pumanifakucharingushisutemu] series.
AFJW01 JW series master interface specification
Correspondence controller series | New satellite JW300/30H/20H series | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Number of support interfaces | JW300: To basis/increase base (rack 0-7) up to 64 JW30H: To basis/increase base (rack 0-3) up to 32 JW20/20H: To basis/increase base up to eight The number is a total value as for all special I/O units. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Board type | Special I/O unit(I/O relay 16 points | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
I/O number | 4 all pile mode: 2560 or less Point (Bit-Bus: 512 points or less/Word-Bus: 2048 or less point) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AnyWireBus port | One port and detachable terminal stand | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connected the number | 128 or less | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transmission distance | The total extension 100m, 200m, 500m, and 1km are selected. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transmission cycle time Unit[msec] (one cycle time value) |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RAS function | Transmission line disconnection position detection function, transmission line short-circuit detection function, and transmission power supply decrease detection function | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connecting cable | Two general-purpose wicks/4 Wick cable (VCTF 0.75-1.25sq) Special flat cable (0.75sq) and general-purpose electric wire(0.75~1.25sq) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power supply | +5V±5% 0.33A (supply from JW side) DC24V +15–10% ripple 0.5Vp-p or less About 0.2A or less in current(When 128 in the terminal is connected, the load current is not included. ) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ambient temperature of use | 0℃~+55 ℃ (preservation temperature :- 20℃-+75℃) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Use humidity | 10%~90%RH (dewfall) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Atmosphere | Causticity gas and flammability gas |