VSC-5600S
Air-Cooled Type
VSC-5600S
High-power model, Demonstrate the ability in the field of various
cooling capacity (w) | 5200/5600 |
---|---|
Voltage Rating (v) | Three phase AC200 |
External dimensions | H1110×W470×D500 |
Volume (kg) | 94 |
Cooling Method | Air-Cooled type |
---|---|
Cooling Capacity(W) | 5200/5600 |
Tuning Form/Setting Criteria | Room temperature, Body temperature |
Tuning Form/Control Target | Inlet oil temperature, Outlet oil temperature |
Tuning Form/Tuning Range (°C) | For setting the reference temperature, -19.9 ~ 19.9 |
Non-removable Type/Control Target | Inlet oil temperature, Outlet oil temperature |
Non-removable Type/Control Range (°C) | 5-50 |
Oil Viscosity (mm2)(S) | 1.4-200 |
Usable Oil Types | Lube Oil , Hydraulic Mineral Oil |
Use Area Temperature (°C | 5~50 |
External Dimensions (mm) | H1110×W470×D500 |
Volume (kg) | 94 |
Coating Color | Light Beige Munsell No-5Y7.0 / 1 Semi-gloss |
Rated Voltage (V) | Three-phase AC200 |
Consumption Current (A) | 7.1/7.3 |
Wattage (W) | 1650/2100 |
Coolant | R407C 1150g |
Noise (dB) | 63 |
Pump/Rated Output (W) | 750 |
Pump/Exhaust Volume (ℓ/min) | 30.0/36.0 |
Relief Valve Pressure Setting (MPa) | 0.6 |
Pipes/Oil Inlet Connection Diameter | Rc3/4 |
Pipes/Oil Outlet Connection Diameter | Rc3/4 |
Pipes/Oil Drain Connection Diameter | Rc1/8 |
Safety Circuit/Compressor | Temperature protector, Overcurrent relay |
Safety Circuit/Refrigeration Cycle | pressure switch |
Safety Circuit/Pump | Overcurrent relay, Relief valve |
Safety Circuit/Circuit Board | Fuse |
Input-Output/Alarm Output | Equipment abnormalities, Condensing temperature anomaly |
Input-Output/Circulation Oil Temperature Output | Upper temperature limit, Lower limit temperature, Upper and lower limit temperature (2 points) |
Input-Output/Control Input | Auto-scale, Auto Level, Manual |
Input-Output/External Thermista | Operation is stopped Compressor operation, Pumping operation |
Input-Output/External Thermista | 2W (Optional) |
Input-Output/RS-232C | 3W |
Cooling capacity, power consumption, current consumption, 35°C ambient temperature, which is the value at the time of 35°C (ISO VG5) oil temperature.Lack of lubrication liquid cutting highly volatile (liquid), polishing (liquid), liquid water and water-soluble, liquid chemicals and food, gasoline, kerosene, such as thinner, hydraulic fluids, flame retardant can not be used.
Dimension
(1)Operation display panel
(2)Filter
(3)Leg
(4)Oil piping port (outlet side): RC 3/4
(5)Oil piping port (inlet side): RC 3/4
(6)Oil drain port: RC 1/8
(7)Hanging bracket
(8)Wire inlet (sides): for conduit
(9)Outlet (top panel)
(10)Outlet (rear)
(11)Outlet (sides)
Characteristic cooling capacity
Operating condition
(1)Outlet temperature sensor: liquid temperature sensor
(2)Airframe temperature tuning formula: control scheme
(3)ISO VG5 oil use