APISTE Heat Resistant ENC-2800HL
Heat Resistant
ENC-2800HL
FA: Heat-resistant cooler out-of-the-box.
Cooling capacity (w) | 2500/2800 | Voltage Rating (v) | Three phase AC200 |
---|---|
Mount type | Side mount |
Ecternal dimensions | H1455×W480×D260 |
Volume (Kg) | 72 |
Mount Type | Side-mount |
---|---|
Cooling Capacity (W) | 2500/2800 |
Setting Temperature Range (°C) | 30~70 |
Use Area Temperature (°C) | 30~70 |
Use Area Humidity (%RH) | 10-85(-45℃)、10-45(-55℃)、10-30(-65℃)、10-20(-70℃) |
External Dimensions (mm) | H1455×W480×D260 |
Volume (kg) | 72 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Three phase AC200 |
Consumption Current/Rating (A) | (At 35 ℃ ambient temperature) 5.0/5.2 |
Consumption Current/MAX (A) | (At 70 ℃ ambient temperature) 6.9/7.3 |
Starting Current (A) | 30 |
Consumption Voltage/Rating (W) | (At 35 ℃ ambient temperature) 1000/1190 |
Consumption Voltage/MAX(W) | (When the outside air temperature of 70 ℃) 1800/2150 |
Noise Resistance | 1.5kV (50ns, 1μs, common pulse width, Normal mode, caused by noise simulator) |
Vibration Resistance | 5Hz frequency 20mm total amplitude |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant | R-134a 933g> |
Noise (dB) | 67/72 |
External Output | Compressor operation. Temperature anomaly in the panel. Compressor overcurrent. Abnormally high temperature compressor. Abnormal pressure compressor (250V 2A). Relay output. |
Display | Power (white), Operation (green), Alarm (red) Lamp display |
Note:
Outside air temperature 35°C , 35°C rated capacity when the set temperature in the panel: cooling capacity (measurement conditions: air enthalpy method by JIS-C-9612). Outside air temperature of 70°C, 70°C rated capacity when the set temperature in the panel will be 900/1000W.Please read instructions carefully before use, please use properly.
3m length outside the machine code: the power supply line (1)
3m length of the outside of code: line operation and alarm output (2)
Alarm output line operation and (2) is, in fact, each output line of the temperature anomaly in the Van / overcurrent compressor / compressor abnormal temperature / pressure abnormality compressor / compressor operation has come out.
Cut Mounting
Standard panel cut (left)
Diagram is viewed from the outside control panel.When processing, please keep the thread pitch.
There are (with some exceptions), the panel cut dimensions can be changed without prior notice minimum standard panel cut, but will not change even after the model change.
minimum cut panel (right)
ability characteristic graph
Cooling capacity measurement conditions characteristic graph
ENC-2800HL When using maximum allowable ambient temperature in an environment close to the FA cooler, please consult our sales representative