ANATOM 78S M12 / ANATOM 98S M12
Non contact coded safety switches – Non stand-alone operation
Description
-
ANATOM 78S M12:
- Decoding by „ACOTOM®―2 Process
- LED status display of the correct code recognition
- Auxiliary output for automation control or light
- Static outputs
- Large switching distance
- Built-in M12 connector
Technical data:
- Switching distance Sn (closing): 8 mm
- Switching distance Sn (opening): ± 7mm
- Hysteresis/Misalignment: + 3mm
- Power supply: 24V AC/DC; –15% / +10%, 50/60 Hz
- Current consumption: 42 mA/DC; 70 mA/AC
- Safety outputs: 2 static outputs ;24V DC/800mA @ 25°C
- Auxiliary output: 1 PNP/NO, 250mA
- Coding principle : ACOTOM®2
- Temperature operation: -20°C to +60°C
- Max. switching frequency: 500μs
- Resistance to vibration: 30 g / 11 ms
- Shock stress : 10-55 Hz, 1,5 mm
- Protection class: IP67
- MTTFd/DC : 335 years / 99%
- Housing: polycarbonate, yellow
- Connection: Built-in M12 connector 8-pin
- Standards: EN60947-5-3, EN954-1, EN13849-1, EN55022, EN61000-6-2; 01/2006; EN61000-6-4; 03/2007
- Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. toIEC 61000-6-4
- Weight Emitter/Receiver: 80g /100g
Safety classification:
- Acc. to EN ISO 13849-1 : 1 switch up to PLe cat.4 Serie wiring possible with 30 switches on a safety relay, up to PLe cat.3
- Certification: CE
-
ANATOM 98S M12 :
- Decoding by „ACOTOM®2 Process
- LED status display of the correct code recognition
- Auxiliary output for automation control or light
- Static outputs
- Large switching distance
- Built-in M12 connector
Technical data:
- Switching distance Sn (closing): 8 mm
- Switching distance Sn (opening): ± 7mm
- Hysteresis/Misalignment: + 3mm
- Power supply: 24V AC/DC; –15% / +10%, 50/60 Hz
- Current consumption: 42 mA/DC; 70 mA/AC
- Safety outputs: 2 static outputs ;24V DC/800mA @ 25°C
- Auxiliary output: 1 PNP/NC, 250mA
- Coding principle : ACOTOM®2
- Temperature operation: -20°C to +60°C
- Max. switching frequency: 500μs
- Resistance to vibration: 30 g / 11 ms
- Shock stress : 10-55 Hz, 1,5 mm
- Protection class: IP67
- MTTFd/DC : 335 years / 99%
- Housing: polycarbonate, yellow
- Connection: Built-in M12 connector 8-pin
- Standards: EN60947-5-3, EN954-1, EN13849-1, EN55022, EN61000-6-2; 01/2006; EN61000-6-4; 03/2007
- Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. toIEC 61000-6-4
- Weight Emitter/Receiver: 80g /100g
Safety classification:
- Acc. to EN ISO 13849-1 : 1 switch up to PLe cat.4 Serie wiring possible with 30 switches on a safety relay, up to PLe cat.3
- Certification: CE