ANATOM M18
Non contact coded safety switches – Non stand-alone operation
Description
- Decoding by „ACOTOM®―2 Process
- LED status display of the correct code recognition
- Misalignment : ±30° in rotating movement
- Auxiliary output for automation control or light
- Metal housing CuNi with M12 quick connector
- Static outputs
- Unlimited life expectancy
Technical data:
- Switching distance Sn (closing): 6 mm
- Switching distance Sn (opening): ± 30° rotation
- Hysteresis/Misalignment: + 2mm
- Power supply: 24V DC; –15% / +10%
- Current consumption: 50 mA/DC
- Safety outputs: 2 static Outputs; 24V DC/800mA @ 25°C
- Auxiliary output: 1 PNP/NC 250mA
- Coding principle : ACOTOM®―2
- Temperature operation: -20°C to +60°C
- Max. switching frequency: 500μs
- Resistance to vibration: 30 g / 11 ms
- Shock stress : 10-55 Hz, 1,5 mm
- Protection class: AC-12, DC-12
- Mechanical life expectancy: IP67
- MTTFd/DC : 225 years / 80%
- Housing: CuNi Metal
- Connection: Built-in M12 8-pin
- Standards: EN60947-5-3, EN954-1, EN13849-1, EN55022, EN61000-6-2; 01/2006; EN61000-6-4; 03/2007
- Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. toIEC 61000-6-4
- Weight Emitter/Receiver: 25g /35g
Safety classification:
- Acc. to EN ISO 13849-1 : 1 switch up to PLe cat.4 Serie wiring possible with 30 switches on a safety relay, up to PLe cat.3
- Certification: CE