Comitronic MASSIMOTTO ANA78S98S .2 M12 | TKK Corporation


MASSIMOTTO ANA78S98S .2 M12

Non contact coded safety switches – Non stand-alone operation

Description

    MASSIMOTTO ANA78S.2 M12:

  • Decoding by „ACOTOM®―2 Process
  • LED status display of the correct code recognition
  • Very easy daisy chain around a machine or on modular elements thanks to the double M12 connector
  • Option double emitter for double hinge-doors
  • NC auxiliary output



Technical data:

  • Switching distance Sn (closing): 8
  • Hysteresis/Misalignment: + 3mm
  • Power supply: 24V AC/DC; –15% / +10%; 50/60Hz
  • Current consumption: 42 mA/DC;70 mA/AC
  • Safety outputs: 2 static outputs ;24V DC/500mA @ 25°C
  • Auxiliary output: 1 PNP/NC 250mA
  • Coding principle : ACOTOM®2
  • Temperature operation: -20°C to +60°C
  • Max. switching frequency: 500μs
  • Resistance to vibration: 30 g / 11 ms
  • Shock stress : 10-55 Hz, 1,5 mm
  • Protection class: IP67
  • MTTFd/DC : 430 years / 94%
  • Housing: Polycarbonate, yellow
  • Connection: 2 built-in connectors M12; 8-pin
  • Standards: EN60947-5-3, EN954-1, EN13849-1, EN55022, EN61000-6-2; 01/2006; EN61000-6-4; 03/2007
  • Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. to IEC 61000-6-4
  • Weight Emitter/Receiver: 66g /163g

Safety classification:

  • Acc. to EN ISO 13849-1 : 1 switch up to PLe cat.4 Serie wiring possible with 30 switches on a safety
relay, up to PLe cat.3
  • Certification: CE
    

MASSIMOTTO ANA98S.2 M12 :

  • Decoding by „ACOTOM®―2 Process
  • LED status display of the correct code recognition
  • Very easy daisy chain around a machine or on modular elements thanks to the double M12 connector
  • Option double emitter for double hinge-doors
  • NO auxiliary output



Technical data:

  • Switching distance Sn (closing): 8
  • Hysteresis/Misalignment: + 3mm
  • Power supply: 24V AC/DC; –15% / +10%; 50/60Hz
  • Current consumption: 42 mA/DC;70 mA/AC
  • Safety outputs: 2 static outputs ;24V DC/500mA @ 25°C
  • Auxiliary output: 1 PNP/NO 250mA
  • Coding principle : ACOTOM®2
  • Temperature operation: -20°C to +60°C
  • Max. switching frequency: 500μs
  • Resistance to vibration: 30 g / 11 ms
  • Shock stress : 10-55 Hz, 1,5 mm
  • Protection class: IP67
  • MTTFd/DC : 430 years / 94%
  • Housing: Polycarbonate, yellow
  • Connection: 2 built-in connectors M12; 8-pin
  • Standards: EN60947-5-3, EN954-1, EN13849-1, EN55022, EN61000-6-2; 01/2006; EN61000-6-4; 03/2007
  • Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. toIEC 61000-6-4
  • Weight Emitter/Receiver: 66g /163g

Safety classification:

  • Acc. to EN ISO 13849-1 : 1 switch up to PLe cat.4 Serie wiring possible with 30 switches on a safety relay, up to PLe cat.3
  • Certification: CE