Comitronic Safety Module C4CK | TKK Corporation


Safety Module C4CK

Safety relays

Description

    CAPTIVE KEY MODULE: the key position overpasses the switch status

Version A

  • Key locked and turned : 4NO+1NC 8A/250V
  • Key removed : 4NC+1NO 8A/250V

Version B

  • Key locked and turned : 4NC+1NO 8A/250V
  • Key removed : 4NO+1NC 8A/250V

Versions A and B

  • 1 line for test loop and 2 LEDs



Technical data:

  • Power supply: 24V AC/DC; -15%/+10%, 50/60 Hz
  • Current consumption: < 3,5 W (DC); < 6,5 VA (AC)
  • Safety outputs: 4 NO; 8A/250V AC
  • Auxiliary output: 1 NC; 4A/250V AC resistive
  • Min. switching power : 50 mW
  • Electrical protection : Surge protector
  • Temperature operation: -20°C to +60°C
  • Protection class: IP20
  • Resistance to vibration: < 20 ms
  • MTTFd/DC : 90 years / 99.9%
  • B10d : AC1: 860000, AC15: 300000, DC13: 300000
  • Housing: Polycarbonate, yellow
  • Connection: Plug-in terminals
  • Dimensions (W x H x D) : 45 x 100 x 111 mm
  • Weight : 227 g
  • Standards:
    • ISO 13849-1
    • EN 55022
    • EN 60947-5-1
    • EN 61000-6-2 : jan 2006
    • EN 61000-6-4 : mar 2007

Safety classification

  • Acc. to EN ISO 13849-1 : PLe Cat.4
  • Certification: CE