Metrol Interface Controller CG1
In order to improve the reliability of the sensing switch.
Common Specifications
Pressure-sensitive switch detection relay output contact (c contact) | CG1-210, CG1-024: AC5 ~ 250V: 0.01 ~ 4A, DC5 ~ 30V: 0.01 ~ 4A (resistance load) CG1-024S: DC5 ~ 30V: 1 ~ 50mA (resistive load) |
---|---|
Disconnection detection relay output contact (a contact) | DC5 ~ 30V: 0.1mA ~ 30mA (resistive load) |
Fit termination resistor | 510Ω |
Installation site temperature | -10 ~ +50 ℃ (freezing, non-condensing) |
External dimensions | 54 (W) × 110 (H) × 115 (D) mm |
Degree of protection (IEC60529) | IP20 |
Applicable standards | CG1-210: European Low Voltage Directive, EN60947-1, EN60947-5-1 CG1-210/024/024S: EN55011, EN61000-4-2 European EMC Directive, 3,4,5,6,11 |
RoHS Directive | Fit |
Break detection with output
wiring eliminates the need to return in combination with-termination resistor with pressure sensitive switch product lines.
· Added a function so that you can equipped with a disconnection detection output new, you can tell the disconnection detection result to the external controller or the like. (WB +, WB-)
Holds a detection result detects the momentary disconnection.
- It is the CE marking.
- It can switch from external output mode self-holding output / direct.
- It does not hold on the state of the pressure sensitive switch, output mode directly outputs directly to the state of the pressure sensitive switch as it is.
- It can be mounted on a DIN rail at the touch of a button.
- It is 3 model configuration CG1-024 of CG1-210, DC power input of AC power input, the CG1-024S of the signal output.
Specification
Model | Input voltage | Power consumption | Mass |
---|---|---|---|
CG1-210 | AC100 ~ 240V ± 10% 50/60Hz | 5.5VA maximum | About 280g |
CG1-024 | DC24V ± 10% | Up to 2.0W | About 240g |
CG1-024S | DC24V ± 10% | Up to 2.0W | About 240g |