PD60/PD65
CE Approved
CE : EMC Directive
Features
2D code quality verifying function
2D code quality verifying function based on ISO/IEC15415, enables the unit to grade the quality of the 2D codes.
Parameters |
---|
Decode |
Symbol Contrast |
Fixed Pattern Damage |
Grid Non-uniformity |
Axial Non-uniformity |
Modulation |
Unused Error Code |
Oil-resistant construction (IP67G*2) allows for peace-of-mind even in oily conditions.
Out of consideration for actual usage environments, we have created the industry’s first oil-resistant construction (IP67G*2) to allow peace-of-mind when using even with gloves covered in machine oil or detergent.
200mm Long Range.
A 200mm long range lens (ANPD060-25) is fitted out of consideration for the attachment locations possible with industrial equipment.
Control of Lighting Possible
Control of lighting sections.
Allows for stable reading regardless of variations in background, reflective properties and material quality of the marked object.
Dual lighting (PD65 only)
Reading under the optimum lighting conditions is made possible by the automatic light switching function, which switches between 2 lighting patterns to allow greater improvement of the accuracy of reading of direct marking.
Double Signal Notification (PD65 only)
Whether reading is possible or not can be confirmed visually during operation.
Ready to Read…Green Light + Buzzer
Read Not Possible…Orange Ligh
Improved Reading Accuracy
Development of original algorithm with image processing technology cultivated over 20 years by Panasonic Industrial Devices SUNX.
We have greatly improved the accuracy of reading direct marking on metal, which is highly problematic for automatic reading, and greatly improved the image detection abilities with image correction using our new preprocessing functions and a new library.
Real-time Image Storage
Realization of traceability. Images with read errors (or all images) can be stored in the main unit.
In addition, using the free utility tool PDTOOL, images can be transferred to a PC and stored in specified folders in real time.
Construction with Emphasis on Maintenance
Just in case some problem occurs with the product, the controller part and cable part are connected with an oil-resistant connector, allowing the controller part to be replaced immediately. This practical construction eliminates the need for troublesome cable tracing and re-laying and allows priority to be given to restoring the work environment.
Dedicated Software Tool “PDTOOL” for Easy Setup
The software tool “PDTOOL” has been enhanced to allow settings to be made easily even with the more advanced functions.
PDTOOL can be downloaded free-of-charge from our Web site.
Further Improvement of Decoding Capabilities with Pre-Processing Functions
In pre-processing, various original algorithms are applied to images of difficult-to-read 2D codes to improve their readability.
In the past, read accuracy was improved for stamp errors (stained, chipped, tilted, flipped or black/white reversed codes) on hard-to-read metal surfaces.
Guide light red LED enables easy fitting and installation
Two red-LED guide lights allow quick installation of the unit in the optimum position.
Applications
Supports 2D codes indicated on a great variety of applications.
Other applications
Printing type (Direct printing)
- Laser marking
- Stamping
- Ink jet printing
Glass boards, wafers, printed circuit boards, etc.
Metal parts, engines, etc.
Automotive components, packages, paper, cardboards, printed circuit boards, etc.
Item | Specification | |
---|---|---|
PD60 | PD65 | |
Rated operating voltage | 24 V DC | |
Operating voltage range | 21.6 to 26.4 V DC (including ripples) | |
Rated current consumption | 0.5 A max. | |
Ambient temperature in use | 0 to +40?C | |
Storage ambient temperature | -20 to +60?C (no freezing or condensation) | |
Ambient humidity in use | 35 to 85%RH (at 25?C no freezing or condensation) | |
Storage ambient humidity | 35 to 85%RH (at 25?C no freezing or condensation) | |
Noise immunity | 1000 V pulse width 50 ns/1 ?s (using noise simulator method) | |
Vibration resistance | 10 to 55 Hz, 1 sweep/min. Double amplitude of 1.5 mm. 30 min. each in X, Y and Z directions | |
Shock resistance | 196 m/s2, 5 times each in X, Y and Z directions | |
Insulation resistance (initial) |
Min. 100Mohm (with a 500 VDC isolation resistance tester) *1Parallel input/parallel output, parallel input/power,parallel input/functional earth, parallel output/power,parallel output/functional earth, power/functional earth. |
|
Breakdown voltage(initial) | 500V AC/1 minute (600V AC/1 second) Cut-off current 10mA *1Parallel input/parallel output, parallel input/power, parallel input/functional earth, parallel output/power,parallel output/functional earth, power/functional earth. |
|
Protective Construction | IP67G *2 | |
Mass *3 | Approx: 500 g | Approx: 700 g |
*1 Evaluation was carried out with the primary side power supply varistor and capacitor removed from the internal circuit of the device.
*2 Evaluation was carried out with the USB cable not connected and the waterproof cap in place.
*3 Weight includes power supply I/O cable.