Model name |
PAF500F24 |
PAF500F48 |
PAF600F24 |
PAF600F48 |
PAF700F48 |
Output voltage |
12V |
28V |
3.3V |
5V |
12V |
28V |
12V |
28V |
12V |
28V |
12V |
28V |
Input voltage range |
19-36VDC |
18-36VDC |
36-76VDC |
20-36VDC |
19-36VDC |
36-76VDC |
Output voltage range |
-40~ +10% |
-40~ +20% |
-40~ +10% |
-40~ +10% |
-40~ +15% |
Parallel operation |
Possibe |
line regulation |
24mV |
56mV |
10mV |
24mV |
56mV |
24mV |
56mV |
24mV |
56mV |
24mV |
56mV |
within nominal input voltage range at constant load |
Load regulation |
24mV |
56mV |
10mV |
24mV |
56mV |
24mV |
56mV |
24mV |
56mV |
24mV |
56mV |
no load to full load at constant input voltage |
Cooling |
Conduction cooling (Heatsink & airflow has to chosen according to instruction manual ) |
Operating ambient temperature |
Baseplate temperature : -40~+100°CAmbient temperature : above -40°C |
Withstand voltage |
Input-output : 1.5kVDC, Input-baseplate 1.5kVDCinput-baseplate 500VDC, output-chassis : for 1min |
Safty standard |
Approved to UL1950,CSA60950 , EN60950 |
Approved to UL1950,CSA950 , EN60950 |
Approved to UL1950,CSA60950 , EN60950 |
Fanctions |
Over voltage protection,Over current protection,Remote on/off control |