PH300S/600S-SERIES | TKK Corporation


PH300S/600S-SERIES

Model name

Features

  • CE marking (Low voltage Directive)
  • Compact DC-DC power module

    Large power 300W/600W

    High power density : 61.6W/inch³ (600W type)

    600W type : 146 x 86 x 12.7 mm

    300W type : 83 x 86 x 12.7 mm
  • Wide baseplate temperature : -20~+100°C
  • Conduction cooling

  • Wide input voltage range
  • DC48V input : DC36~76V , DC280V input : DC200~400V

  • 2 year warranty

Specifications

Input voltage range PH300S48 (300W type): DC36~76V
PH300S280 (300W type)
PH600S280 (600W type) : DC200~400V
Output voltage range 10%(12V~28V types) , -10%~+20%(3.3V,5V and 48V types )
(By TRM terminal and external resistor)
Output voltage range is different according to input voltage.
line regulation 0.4%,within nominal input voltage range at constant load (3.3V output : 40mV)
Load regulation 0.8%.no load to full load at constant input voltage (3.3V output : 40mV)
Cooling Conduction cooling (Heatsink & airflow has to chosen according to instruction manual )
Operating ambient temperature Baseplate temperature : -20~+100°C (output derating is different according to condition)
Ambient temperature : above -20°C
Withstand voltage DC48V input : Input-output : 1.5kVAC, input-baseplate : 1.5kVAC, output-chassis : for 1min
DC280V input : Input-output : 3.0kVAC, input-baseplate : 2.5kVAC, output-chassis : for 1min
Safty standard Approved UL1950,CSA950 and EN60950
Fanctions Over voltage protection , Over current protection, Thermal protection, Remote sensing, Remote on / off control, Inverter good signal (IOG terminal), CS terminal (Load current balancing is possible with external control circuit parallel operation)

Product lineup

Model name Output voltage Output current Output power
PH300S48(input 48VDC) PH300S48-3.3 3.3V 50A 165W
PH300S48-5 5V 50A 250W
PH300S48-12 12V 25A 300W
PH300S48-15 15V 20A 300W
PH300S48-24 24V 12.6A 302.4W
PH300S48-28 28V 10.8A 302.4W
PH300S48-48 48V 6.3A 302.4W
PH300S280(input 280VDC) PH300S280-3.3 3.3V 50A 165W
PH300S280-5 5V 50A 250W
PH300S280-12 12V 25A 300W
PH300S280-15 15V 20A 300W
PH300S280-24 24V 12.5A 300W
PH300S280-28 28V 10.8A 302.4W
PH300S280-48 48V 6.3A 302.4W
PH600S280(input 280VDC) PH600S280-3.3 3.3V 100A 330W
PH600S280-5 5V 100A 500W
PH600S280-12 12V 50A 600W
PH600S280-15 15V 40A 600W
PH600S280-24 24V 25A 600W
PH600S280-28 28V 21.5A 602W
PH600S280-48 48V 12.5A 600W

As for the mention contents of this page, understand beforehand because it sometimes changes.