Feature
SOUNDING BOB TYPE LEVEL INDICATOR KSL Series
The sounding type level meter has a robust housing and exerts an excellent durability under severe ambient conditions.
It can be used for various processes.
- As a simple mechanical detection method is used for measurement, the meter is not easily affected by measured substances and ambient conditions and provides stable indications.
- The CPU built in the meter enables direct pulse output and analog output from the sensing unit.
(KSL-T8, KSL-MT) - A trouble alarm contact is provided as standard. (KSL-T8, KSL-MT)
- A built-in CPU self-check mode and other various check modes are provided.
- As an auto-measuring timer is built in the sensing unit, it is not necessary to secure any exterior space for the timer.
Operating Principles
When a start signal is input, the motor is activated and the metering tape is winded off to descend the weight. Accordingly, a pulse is sent at regular intervals. When the weight touches the measurement surface, the motor is stopped and the measurement value on the level meter is output. Then, the motor winds up the metering tape to return to the original position.
Standard Specification
Specification/Model | KSL-T8 | KSL-T2 |
---|---|---|
Power Voltage | 100VAC or 200VAC,Single-phase 50/60Hz | 100VAC or 200VAC,Single-phase 50/60Hz |
Consumption | Max.150VA | Max.150VA |
Allowable Temperature | ambient : -10℃~+50℃(No freezing/condensation)Inside tank : -10℃~+80℃(No freezing/condensation) | ambient : -10℃~+50℃(No freezing/condensation)Inside tank : -10℃~+80℃(No freezing/condensation) |
Measuring Span | Standard 20m(40m Option) | Standard 20m(40m Option) |
Measuring Method | Pulse Counting | Pulse Counting |
Measuring Unit | 1 pulse/10cm,or 1 pulse/1cm | 1 pulse/10cm |
Measuring Accuracy | ±10cm / ±1cm | ±10cm |
Motor | Single-phase, Reversible,Output 40W30 minutes rating, with brake | Single-phase, Reversible,Output 40W30 minutes rating, with brake |
Body material | AC | SPCC |
Mounting Method | JIS 5K 125A | JIS 10K 100A |
Enclosure Rating | IP-67 | Equivalent to IP-33 |
Output Signal | Current signalDC4~20mA(indicate remains)DC20~4mA(indicate vacated portion)(User can set up either one)Pulse contact signal1 pulse / 1cm(No-volt signal)1pulse / 10cm(User can set up either one) | Possible to control 4-20mA output by combining an optional control unit and P / I converter. |
Output Contact | Reset Contact/for Remote Indication Counter,ON at the time of resetFailure Alarm Contact/Flickers when the measuringtape is cut off.The contact is closed whenthe weight is buried. | Possible to control both upper and lower output by combining an optional control unit and P / I converter. |
Product Lineup
KSL-T8
KSL-MT
KSL-T2
KSL-W2B
In addition to the above, various specifications are available.
For more information, see respective catalogs or contact us by phone or mail.