MASSIMOTTO X5 M12 AR / SR

Non con contact coded safety switches – Stand alone operation

Description

  • With reset loop integrated
  • Integrated self-control „ACOTOM®3“
  • LED status display of the correct code recognition
  • High safety category and performance level: PLd Cat.3
  • No additional safety relay necessary: easy to implement into an existing system without modifying all the electrical diagrams
  • Option double emitter for double hinge-doors

Technical data:

  • Switching distance Sn (closing): 8
  • Switching distance Sn (opening): nc
  • Hysteresis/Misalignment: +3 mm
  • Power supply: 24V AC/DC –15% / +10%, 50/60 Hz
  • Current consumption: 57 mA/DC, 88 mA/AC
  • Safety outputs: 2 NO output 48V DC, 2A
  • Auxiliary output: 1 PNP/NC, 250mA
  • Coding principle: ACOTOM®3
  • Temperature operation: -20°C to +60°C
  • Max. switching frequency: 10 ms
  • Resistance to vibration: 10 g / 11 ms
  • Shock stress : 10-55 Hz, 1,5 mm
  • Protection class: IP67
  • Mechanical life expectancy: 50.000.000 operations
  • Housing: Polycarbonate, yellow
  • Connection: Built-in M12 connector, 8-pin
  • Standards:EN60947-5-1, EN954-1, EN13849-1
  • Electromagnetic immunity : Acc. to IEC 61000-6-2, acc. toIEC 61000-6-4
  • Weight Emitter/Receiver: 66g / 148g
  • Certification: CE



Normes :

  • Performance Level (PL) = d
  • Safety category = 3 ou SIL2
  • MTTFd = 210 years
  • DC = 99 %
  • CCF = 90 %
  • TM= 20 years