Paint Circulation Pumps | TKK Corporation


Paint Circulation Pumps

Paint Circulation Pumps


Viscount 2-Ball Pump

Viscount 2-Ball Pump

Hydraulic Piston Pumps

Hydraulic powered piston pumps for factory and outdoor operation

The rugged pump lower construction with Severe Duty rods and cylinders reduces downtime and extends the interval between
repairs. The simple construction makes service and repair fast and easy. The efficient hydraulic power makes these
pumps the ideal choice for factory and outdoor mobile use, even at below freezing temperatures. Models include Viscount
I 1000 and 3000 and Viscount II 1000, 2000, 2600, 4500 and 5000.

Features

  • Clean, quiet operation with no airborne contamination
  • Up to three times more energy efficient than comparable compressed air systems
  • Positive displacement, 2-ball piston design provides uniform and easily controlled delivery
  • Reduce routine maintenance and cut repairs time in half of comparable pump lowers
  • Eliminate downtime without ice build-up

Specifications

Viscount I 1000 Pump
Maximum Fluid Outlet Pressure 1000 psi
Maximum Hydraulic Input Pressure 1000 psi
Maximum Hydraulic Fluid Volume 3 gpm
Fluid Delivery Rate at 60 cycles/min 3 gpm
Maximum Hydraulic Fluid Temperature 130°F
Cycles per Gallon (3.8 Liter) 20
Wetted Parts 303 & 304 stainless steel, nitrile rubber, polyethylene,
Weight 33 lb
Viscount II Hydraulic Motor
Maximum hydraulic fluid input pressure: Models 217022, 217338, 235345. 1500 psi
Maximum hydraulic fluid input pressure: Model 262818 1800 psi
Maximum hydraulic fluid input pressure: Model 24W139 1900 psi
Maximum hydraulic fluid flow 12 gpm
Hydraulic fluid consumption 1 gal per 5 cycles
Effective piston area 4.9 sq in
Piston rod diameter 2.5 in
Stroke length 4.69 in
Thrust at 1500 psi (10 MPa, 103 bar) 7300 psi
Weight approximately 96 lb

Viscount I 3000 Pump
Maximum outlet pressure 3000 psi (21 MPa, 207 bar)
Fluid delivery rate 5/8 gpm at 2500 psi
Fluid outlet size 3/8 npt(f)
Fluid inlet size 3/4 npt(m)
Maximum recommended pump speed 40 cycles/min.
Hydraulic fluid consumption 6.5 ounces per cycle; or one gallon per 19.5 cycles
Hydraulic input pressure 1000 psi maximum
Hydraulic inlet 3/4–16 UNF–2A, 37 flare(m)
Hydraulic outlet size 7/8–14 UNF–2A, 37 flare(m)
Wetted parts see manual 306981
Weight 37 lb
Viscount II 4500 Pump
Maximum hydraulic input pressure 1500 psi
Maximum pump output pressure 4500 psi
Maximum recommended pump speed 50 cycles per minute – 3.3 gpm
Hydraulic fluid consumption 0.2 gal per cycle
Wetted parts See manual 307728

Download PDF

Viscount 4-Ball Pump

Viscount 4-Ball Pump

Hydraulic Piston Pumps

Hydraulic powered piston pumps for more efficient operation

Graco’s Viscount 4-Ball pumps are up to three times more efficient than comparable compressed air systems. The simplified
lower design means fewer parts and fast, easy repairs for low cost of ownership.

Highlights:

  • Offers high volume output at low cycle rates
  • Provides large output per cycle to reduce pump wear and maintenance
  • Reduces sealing area to minimize throat leakage
  • Produces low-shear output for metallic or waterborne paint circulation
  • Flushes easily and offers quick color changes

Features

  • Lower operating costs (up to three times more efficient than pneumatics)
  • Quiet operation
  • Reduced downtime with hydraulic motor
  • No icing
  • Enclosed wet cup minimizes operator interaction for reduced maintenance

Sealed 4-Ball Lowers

  • No TSL required
  • Ultralife Series ceramic coating holds up to the harshest materials, including waterborne paints
  • Completely sealed fluid section can be used almost anywhere, including catalyst and moisture sensitive materials
  • Compatible with existing Bulldog, NXT, President, Viscount, E-Flo, and E-Flo DC motors
  • Open wet cup version is also available

Specifications

Viscount 4–Ball Pumps
Maximum Fluid Temperature Rating 150°F
Maximum Hydraulic Motor Fluid Temperature 134°F
Hydraulic Oil Consumption See Viscount 4–Ball Pump manual.
Hydraulic Oil Inlet See Viscount Motor manual.
Fluid Inlet See 4–Ball Lower Pump manual.
Fluid Outlet See 4–Ball Lower Pump manual.
Wetted Parts See 4–Ball Lower Pump manual.
Sound Data See Viscount Motor manual.
Maximum Working Fluid Pressure
Viscount I Plus, 750 cc Lower 450 psi
Viscount I Plus, 1000 cc Lower 300 psi
Viscount I Plus, 1500 cc Lower 225 psi
Viscount I Plus, 2000 cc Lower 167 psi
Viscount II, 2000 cc Lower 460 psi
Viscount II, 3000 cc Lower 400 psi
Viscount II, 4000 cc Lower 300 psi
Maximum Hydraulic Working Pressure
Viscount I Plus 1500 psi
Viscount II 1200 psi
Fluid Flow at 60 cycles per minute
Viscount I Plus, 750 cc Lower 9.6 gpm
Viscount I Plus, 1000 cc Lower 14.1 gpm
Viscount I Plus, 1500 cc Lower 19.4 gpm
Viscount I Plus, 2000 cc Lower 26.8 gpm
Viscount II, 2000 cc Lower 31.5 gpm
Viscount II, 3000 cc Lower 47.3 gpm
Viscount II, 4000 cc Lower 63.0 gpm
Fluid Output per Cycle
Viscount I Plus, 750 cc Lower 610 cc
Viscount I Plus, 1000 cc Lower 890 cc
Viscount I Plus, 1500 cc Lower 1230 cc
Viscount I Plus, 2000 cc Lower 1690 cc
Viscount II, 2000 cc Lower 2000 cc
Viscount II, 3000 cc Lower 3000 cc
Viscount II, 4000 cc Lower 4000 cc
Weight
Viscount I Plus, 750 cc Lower 74 lb
Viscount I Plus, 1000 cc Lower 75 lb
Viscount I Plus, 1500 cc Lower 76 lb
Viscount I Plus, 2000 cc Lower 77 lb
Viscount II, 2000 cc Lower 150 lb
Viscount II, 3000 cc Lower 215 lb
Viscount II, 4000 cc Lower 217 lb