Model name

Features

  • CE marking (Low Voltage Directive)
  • PFHC module
  • Conforms to IEC 1000-3-2
    High power factor : 0.95, high efficiency : 90%
    Input : 85~265VAC
    Output : 500,1000W

  • Wide baseplate temperature : -20~+85°C
  • Conduction cooling

  • Provided in-rush current limiting
  • N+1 parallel redundant operation
  • 2 year warranty

Specifications

Input voltage range 85~265VAC (50/60Hz) PFHC range : 85~255VAC (50/60Hz)
Output
voltage/current
PF500A-360 /85~265VAC input : DC360V 1.4A 504W
170~265VAC input : DC360V 2.1A 756W
PF1000A-360 /85~265VAC input : DC360V 2.8A 1008W
170~265VAC input : DC360V 4.2A 1512W
Output derating by input voltage /PF500A : 80% for 85VAC, 100% for 100~265VAC
PF1000A : 85% for 85VAC, 100% for 95V~265VAC
Effeciency (typ) 90% (100VAC, full load), 94% (200VAC, full load)
Power factor 0.95 (100VAC/200VAC at full load)
In-rush current In-rush current limiting circuit : External limit resistor
Parallel operation N+1 redundant operation. Output current balancing (PC terminal)
Cooling Conduction cooling (Heatsink& airflow has to be chosen according to instruction manual)
Operating ambient temperature Baseplate temperature : -20~+85°C (output derating is different according to condition)
Ambient temperature : above -20°C
Withstand voltage Input/output terminal to baseplate : 3.0kVAC for 1min
Safety standard Approved by UL1950, CSA234 and EN60950 (BSI)
Functions Over voltage, Thermal protection, PFHC power on signal (ENA terminal), Inverter good signal (IOG terminal), Auxiliary power supply for external signal(AUX terminal)

Product lineup

Model name Nominal
Voltage
range
Input voltage
range
PFHC operation
input voltage
range
Input
current
(typ)
Nominal
output voltage
Max. output
current
Max. output
power
PF500A-360 100-240VAC 85-265VAC
(47-63Hz)
85-255VAC
(47-63Hz)
5.6A 360VDC 1.4A 504W
200-240VAC 170-265VAC
(47-63Hz)
170-255VAC
(47-63Hz)
4.0A 360VDC 2.1A 756W
PF1000A-360 100-240VAC 85-265VAC
(47-63Hz)
85-255VAC
(47-63Hz)
11.2A 360VDC 2.8A 1008W
200-240VAC 170-265VAC
(47-63Hz)
170-255VAC
(47-63Hz)
8.0A 360VDC 4.2A 1512W