Features
OXYGEN ANALYZER OXITEC5000
The gas sealed cell is produced by a special sealing technology! High precision, high stability, and long life duration are ensured!
- Automatic startup
- Packaged with installation accessories and cable
- Functions are kept by the minimum maintenance.
- Components can be replaced by the customer.
- Gas sampling and processing are not needed.
- Suitable for application under high temperature conditions (max. 1400°C)
Operating Principles
The oxygen concentration in a gas is measured from the difference in the oxygen partial pressure (pressure that oxygen accounts for in the atmospheric pressure) between the reference gas in the meter body and the measured gas.
Standard Specification
Items | OXITEC 5000 | |
---|---|---|
Function | Sensitivity | Below 1ppm O2 |
Accuracy | ±0.2%(from measured value) | |
Resolution(A/D Converter) | 14 Bit | |
Controller | Housing | A)Wall-hanging Type with a window box SS,IP-65400mmx300mmx225mm |
B)Built-in Type with a window box SS,IP-54177mmx483mmx360mm | ||
C)Wall-hanging explosion-proof Typewith a round window box AC280mmx300mmx240mm | ||
Power Voltage | 115VAC or 230VAC 50/60Hz | |
Power Consumption | 100-200VA(400VA at start-up) | |
Recommended Fuse | 10A | |
Temperature | -20~+55℃(other temp on request) | |
Range | 2 measuring ranges,0-99% adjustable | |
Output Analogue | 0/4-20mA max.500Ω resistance load | |
Output Indication | System error,maintenance | |
Output Relay contact | System error,maintenanceUpper limit,Lower limitContact capacity : 230VAC 5A Resistance load | |
Display | LCD/LED Graphic display | |
Interface | RS232C,RS485,bus compatible |
Product Lineup
features
FTIR GAS ANALYZERS
FTIR method: Fourier transform infrared analysis The analyzer continuously measures 12 or more gas components using the unique algorism.
- As a sample gas is measured with the temperature kept high (180°C), high-temperature, high-humidity, and water-soluble gases can be measured.
- It has an excellent corrosion resistance and uses a simple measurement method that does not need water removal.
- As a quantitative analysis system is used, a calibration gas is not basically needed. Only the zero gas measurement is performed using a nitrogen gas.
Operating Principles
Respective molecules that constitute physical properties have their unique frequency of vibration, and only the infrared rays that correspond to the frequency of vibration are absorbed. Thus, the substance can be identified from the frequency distribution at the absorption peak.
Infrared rays regarded as interference light by the interferometer are absorbed by the sample gas in the cell to obtain the frequency intensity specific to each molecule. The spectrum is obtained from the frequency intensity through the Fourier transformation, the mutual interference compensation and absorption band are selected, and then the gas is identified and the concentration is calculated from the library and CLS algorism.
Standard Specification
ENCLOSURE | |
---|---|
Material | SPC(cream:baking paint) |
Dimensions | 2530 x 800 x 800mm |
Weight | 550kg(full system) |
Protection | IP-54 |
AIR CONDITIONING UNIT | |
Cooling capacity | A35℃/A35℃ 1500WA50 c/A35 c 1000W |
Internal circulation | 500㎥/h |
HEATED TUBE | |
Material | Teflon |
Operating pressure | Max.400kPa |
Temperature | Max.200℃ |
Power supply | AC230V (Option:AC115V)120W/m |
SAMPLE PROBE SP2000-H | |
Power consumption | 800W |
Operating temp. | 180℃ |
Filter element | Ceramic 2μm |
Dust loadings | <2g/㎥ |
Probe tube | SUS316 |
Probe length | 1m |
Sample temp. | Max.600℃ |
Sample pressure | 0.4~6bar |
CEMS System
In-Situ
Download PDF