Valcom Pressure Sensor
Middle-High pressure type
Model | VPRT(F) | VPVT(F) | VPRQ(F) | VPVQ(F) |
---|---|---|---|---|
Photo | ||||
Rated output | 1.53mV/V±0.153mV/V (1MPa, 2MPa:1.53mV/V+0.688mV/V-0.20mV/V) |
1.53mV/V±0.153mV/V (1MPa, 2MPa:1.53mV/V+0.688mV/V-0.20mV/V) |
||
Non Linearity | ±0.2%R.C.(1MPa:±0.3%R.C.) | ±0.8%R.C.(1MPa:±1%R.C.) | ||
Hysteresis | ±0.2%R.C.(1MPa:±0.3%R.C.) | ±0.8%R.C.(1MPa:±1%R.C.) | ||
Compensated temperature range | -20~70°C(No condensation or freezing) | -30~70°C(No condensation or freezing) | ||
Safe temperature range | -30~80°C(No condensation or freezing) | -40~100°C(No condensation or freezing) | ||
Temperature effect on zero balance | ±0.2%R.C./10°C | ±0.2%R.C./10°C(*2) | ||
Temperature effect on load | ±0.2%R.C./10°C | ±1%R.C./10°C | ||
Detection method | Strain gauge | |||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | |||
Material | SUS630 or 15-5PH(*1) | |||
Pressure to be measured | Positive pressure, Compound pressure | |||
Rated capacity | 1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 50MPa, 100MPa |
1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 35MPa, 50MPa, 100MPa |
||
Screw size | R3/8(100MPa:R1/2) G3/8(100MPa:G1/2) |
R3/8, G3/8(100MPa:G1/2) | ||
Model | VPG-2TH | VPRS | P3MB | P3MBP |
Photo | ||||
Rated output | 1.5mV/V± (3000×10-6Distortion) ±0.5%R.C. |
1mV/V±0.0025mV/V (500MPa:0.75mV/V±0.0075mV/V) |
3000bar:1.5±0.15%mV/V 5000~15000bar:1mV/V±0.3~±0.8 |
|
Non Linearity | ±0.2%R.C. | ±0.35%R.C. | 3000bar:±0.2% 5000bar:±0.2% 10000bar:±0.4% 15000bar:±0.5% |
|
Hysteresis | ±0.2%R.C. | ±0.1%R.C. | ||
Compensated temperature range | -10~70°C (No condensation or freezing) |
-10~75°C(No condensation or freezing) | -10~80°C | |
Safe temperature range | -20~80°C (No condensation or freezing) |
-20~75°C(No condensation or freezing) | -40~100°C | |
Temperature effect on zero balance | ±0.2%R.C./10°C | ±0.09%R.C./10°C | ±0.1~±0.2% | |
Temperature effect on load | ±0.1%R.C./10°C | ±0.09%R.C./10°C | ±0.1~±0.2% | |
Detection method | Strain gauge | |||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | |||
Material | SUS630 | |||
Pressure to be measured | Positive pressure | |||
Rated capacity | 200MPa | 300MPa, 400MPa, 500MPa | 3000bar, 5000bar, 10000bar, 15000bar | |
Screw size | G1/2 | G1/2(500MPa:G3/4) | M20×1.5 |
(*1) Precipitation hardening system stainless steel
(*2) 100MPa:±1%R.C./10°C
Minute-Low type
Model | VHR3(G3) | VPRNP | [Only a part rated capacity is a production end.] VPMR(G) |
---|---|---|---|
Photo | |||
Rated output | 85±30mV/mA (50kPa:100±40mV/mA) (700kPa:112±42mV/mA) |
100±30mV/1mA | 33±14mV/0.5mA (5kPa:16±7mV/0.5mA) |
Non Linearity | ±0.2%R.C. | ±0.25%R.C. | ±0.2%R.C. (5kPa, 15kPa:±0.3%R.C.) |
Hysteresis | ±0.1%R.C. <700(A):0.2%R.C.> |
±0.05%R.C. | ±0.2%R.C. (5kPa, 15kPa:±0.3%R.C.) |
Compensated temperature range | 0~70°C (No condensation or freezing) |
0~70°C (No condensation or freezing) |
0~70°C (No condensation or freezing) |
Safe temperature range | -20~120°C (No condensation or freezing) |
-40~125°C (No condensation or freezing) |
-20~120°C (No condensation or freezing) |
Temperature effect on zero balance | ±1%R.C./0~70°C(For 25°C) | ±0.2%R.C./10°C (5kPa:±0.5%R.C./10°C) |
|
Temperature effect on load | ±1%R.C./0~70°C(For 25°C) | ±0.2%R.C./10°C (5kPa:±0.5%R.C./10°C) |
|
Detection method | Semiconductor | ||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | Gaseous body, Gas(Inertness, Active) | |
Material | Hastelloy C22 | SUS316L | Semiconductor |
Pressure to be measured | Positive pressure, Negative pressure, Compound pressure, Absolute pressure | Positive pressure, Negative pressure, Compound pressure | |
Rated capacity | 50kPa, 100kPa, 200kPa, 500kPa, 700kPa, 50kPa abs, 100kPa abs, 200kPa abs, 500kPa abs, 700kPa abs |
100kPa, 200kPa, 700kPa, 1700kPa, 100kPa abs, 200kPa abs, 700kPa abs, 1700kPa abs |
5kPa, 15kPa, 35kPa, 50kPa, 100kPa, 200kPa, 350kPa |
Screw size | R3/8, G3/8 | R3/8, G3/8 | R3/8 |
Flush type
Model | VPRF | VFM | VF | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Photo | |||||||||||||||||||||||||||||||||
Rated output | 1.53±0.153mV/V (1MPa:1.07±0.153mV/V) |
0.6~0.8mV/V(1MPa) 0.8~1.0mV/V(2~20MPa) |
Approx. 1mV/V | ||||||||||||||||||||||||||||||
Non Linearity | ±0.5%R.C. | ±0.5%R.O. | |||||||||||||||||||||||||||||||
Hysteresis | ±0.5%R.C. | ±0.5%R.O. | |||||||||||||||||||||||||||||||
Compensated temperature range | -10~50°C(No condensation or freezing) | 0~70°C(No condensation or freezing) | |||||||||||||||||||||||||||||||
Safe temperature range | -10~75°C(No condensation or freezing) | -5~80°C(No condensation or freezing) | |||||||||||||||||||||||||||||||
Temperature effect on zero balance | ±0.8%R.C./10°C | ||||||||||||||||||||||||||||||||
Temperature effect on load | ±0.8%R.C./10°C | ||||||||||||||||||||||||||||||||
Detection method | Strain gauge | ||||||||||||||||||||||||||||||||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | ||||||||||||||||||||||||||||||||
Material | SUS630 or 15-5PH(*1) | SUS630 | |||||||||||||||||||||||||||||||
Pressure to be measured | Positive pressure, Compound pressure | ||||||||||||||||||||||||||||||||
Rated capacity | 1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 50MPa |
2MPa, 5MPa, 10MPa, 20MPa |
1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 50MPa |
||||||||||||||||||||||||||||||
Screw size | G3/8 | G1/4 | G1/8 | ||||||||||||||||||||||||||||||
Model | VTRF | VNF | VPGFS | VPGFM | |||||||||||||||||||||||||||||
Photo | |||||||||||||||||||||||||||||||||
Rated output | 0.5~1.5mV/V | 100±30mV/1mA | 1.5mV/V±20% (3000×10-6Distortion) |
200kPa:0.6mV/V(1200×10-6Distortion) or more 500kPa, 1MPa:1mV/V(2000×10-6Distortion)±20% |
|||||||||||||||||||||||||||||
Non Linearity | ±1%R.O. | ±0.25%R.C. | ±0.5%R.C. | ±1.5%R.C. | |||||||||||||||||||||||||||||
Hysteresis | ±1%R.O. | ±0.05%R.C. | ±0.5%R.C. | ±1.5%R.C. | |||||||||||||||||||||||||||||
Compensated temperature range | -5~150°C | 0~70°C(No condensation or freezing) | 0~50°C(No condensation or freezing) | 0~50°C(No condensation or freezing) | |||||||||||||||||||||||||||||
Safe temperature range | -10~160°C | -40~125°C(No condensation or freezing) | -10~70°C(No condensation or freezing) | -10~60°C(No condensation or freezing) | |||||||||||||||||||||||||||||
Temperature effect on zero balance | ±0.8%R.O./10°C | ±1%R.C./0~70°C (For 25°C) |
±1%R.C./10°C | ±2%R.C./10°C (200kPa:±3%R.C./10°C) |
|||||||||||||||||||||||||||||
Temperature effect on load | ±0.8%R.O./10°C | ±1%R.C./0~70°C (For 25°C) |
±1%R.C./10°C | ±2%R.C./10°C (200kPa:±3%R.C./10°C) |
|||||||||||||||||||||||||||||
Detection method | Strain gauge | Semiconductor | Strain gauge | ||||||||||||||||||||||||||||||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | ||||||||||||||||||||||||||||||||
Material | SUS630 | SUS316L | SUS630 | C1720 | |||||||||||||||||||||||||||||
Pressure to be measured | Positive pressure | Positive pressure, Negative pressure, Compound pressure, Absolute pressure |
Positive pressure | Positive pressure | |||||||||||||||||||||||||||||
Rated capacity | 10MPa, 35MPa | 100kPa, 200kPa, 700kPa, 1700kPa, 100kPa abs, 200kPa abs, 700kPa abs, 1700kPa abs |
5MPa, 10MPa, 20MPa, 50MPa | 200kPa, 500kPa, 1MPa | |||||||||||||||||||||||||||||
Screw size | G1/2-20UNF-2A | G3/4 | G1/8 | G1/8 |
(*1) Precipitation hardening system stainless steel
High-Temperature type
Model | VPRF2 | VPRH2 | VPRH |
---|---|---|---|
Photo | |||
Rated output | 1mV/V±30% | 1mV/V±30% (1MPa:1mV/V±40%) |
1MPa:1mV/V±0.2mV/V 2MPa:1mV/V±0.3mV/V 5MPa, 10MPa:1.5mV/V±0.1mV/V |
Non Linearity | ±0.5%R.C. | ±0.3%R.C. (1MPa:±0.5%R.C.) |
±0.3%R.C. |
Hysteresis | ±0.5%R.C. | ±0.2%R.C. (1MPa:±0.5%R.C.) |
±0.3%R.C. |
Compensated temperature range | -10~150°C(No condensation or freezing) | -10~150°C(No condensation or freezing) | -40~150°C(No condensation or freezing) |
Safe temperature range | -15~150°C(No condensation or freezing) | -15~165°C(No condensation or freezing) | -40~165°C(No condensation or freezing) |
Temperature effect on zero balance | ±0.5%R.C./10°C | ±0.3%R.C./10°C (1MPa:±0.5%R.C./10°C) |
±0.25%R.C./10°C |
Temperature effect on load | ±0.5%R.C./10°C | ±0.3%R.C./10°C (1MPa:±0.5%R.C./10°C) |
±0.5%R.C./10°C |
Detection method | Strain gauge | ||
Typical fluids to be measured | Gaseous body, Gas(Inertness, Active), Hydraulic(Oil, water) | ||
Material | SUS630 | SUS630 | SUS30 or 15-5PH(*1) |
Pressure to be measured | Positive pressure, Compound pressure | Positive pressure, Compound pressure |
Positive pressure |
Rated capacity | 1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 50MPa |
1MPa, 2MPa, 5MPa, 10MPa, 20MPa, 50MPa |
1MPa, 2MPa, 5MPa, 10MPa |
Screw size | G3/8 | R3/8, G3/8 | R1/8 |