Valcom VPRF Series
Pressure Transducer for Flush type Middle High Pressure
- Suitable for measurement of viscous media since the flush type (no feed port) wetted part is hardly clogged up.
- Wetted part constructed integral with diaphragm does not use any sealed liquid, offering durability, reliability and long life.
- High accurate (Non Linearity: ±0.5%R.C.)
Measured medium | Water, oil, gases or other media that will not corrode SUS630 or 15-5PH (precipitation-hardened stainless steel). |
---|---|
Pressure type | Positive pressure can be measured. |
Rated capacity | 1~50MPa |
Specification
Rated Output(R.O.) | 1.5mV/V ±0.15mV/V(1MPa:1.07mV/V ±0.15mV/V) |
---|---|
Non Linearity | ±0.5%R.C. |
Hysteresis | ±0.5%R.C. |
Excitation;Recommended | 5V or less |
Excitation;Maximum | 10V |
Input Terminal Resistance | 350±3.5Ω |
Output Terminal Resistance | 350±5Ω |
Insulation Resistance | 1000MΩ or more (DC50V) |
Compensated Temperature Range (Temperature of medium to be measured) |
-10~50°C(No condensation or freezing) |
Safe Temperature Range (Temperature of medium to be measured) |
-10~75°C(No condensation or freezing) |
Safe Overload Rating | 150%R.C. |
Ultimate Overload Rating | 300%R.C. |
Temperature Effect on Zero Balance | ±0.8%R.C./10°C |
Temperature Effect on Load | ±0.8%R.C./10°C |
Fastening Torque;Recommended | 10~20N・m |
Fastening Torque;Maximum30N・m | |
Connection Screw | G3/8 |
Pressure Port Material | SUS630 or 15-5PH (Precipitation hardening stainless steels) (*1) |
Cable | 4-core shielded (oilproof) cable 3m(Standard) φ6mm|
Weight | Approx. 200g(Cable not included) |
Accessories | Operation manual (1 copy)(Specify English or Japanese.) Test report (1 copy) Aluminum packing(×1)(Copper packing × 1 for 50 MPa model only) |
(*1) Running change planned (since October 2011)