Valcom VF Series | TKK Corporation


Valcom VF Series

Miniature Flush type Pressure Transducer

  • Small design (G1/8 thread)
  • High accurate (Non Linearity: ±0.5%R.O.)
  • Suitable for measurement of viscous media since the flush type (no feed port) wetted part is hardly clogged up.
  • Wetted part constructed integral with diaphragm does not use any sealed liquid, offering durability, reliability and long life.
Measured medium Water, oil, gases or other media that will not corrode SUS630.
Pressure type Positive pressure can be measured.
Rated capacity 1~50MPa

Specification

Rated Output(R.O.) Approx. 1mV/V
Non Linearity 0.5%R.O.
Hysteresis 0.5%R.O.
Excitation;Recommended 6V
Excitation;Maximum

10V
Zero Balance ±0.6mV/V
Input Terminal Resistance 100MΩ or more
Output Terminal Resistance 350±10Ω
Insulation Resistance (*1) 350±10Ω
Compensated Temperature Range
(Temperature of medium to be measured)
0~70°C(No condensation or freezing)
Safe Temperature Range
(Temperature of medium to be measured)
-5~80°C(No condensation or freezing)
Safe Overload Rating 150%R.O.
Temperature Effect on Zero Balance ±0.8%R.C./10°C
Temperature Effect on Load ±0.8%R.C./10°C
Pressure Port Material SUS630
IP Rating Equivalent to IP65
Cable 4.5-4-core shielded cable
Weight 50g(Cable not included)
Accessories Copper packing(×1)

(*1) Applied voltage:50V