Valcom VPMR(G) Series
[Only a part rated capacity is a production end.]
Minute-Low Pressure Transducer for Gas(Inert)
- Measures minute and low pressures (5 to 350 kPa) with high accuracy.(Non Linearity: ±0.2 to 0.3%R.C.)
- For the cable connection to the sensor, “pigtail”, “standard connector” and “waterproof connector” are available.
Measured medium | Dedicated to inert gases (noncorrosive gases) such as air, nitrogen, argon, etc. |
---|---|
Pressure type | Positive, compound and negative pressures can be measured. |
Rated capacity | 5~350kPa |
Specification
Rated Output(R.O.) | 33±14mV/0.5mA(5kPa:16±7mV/0.5mA) |
---|---|
Non Linearity | ±0.2%R.C.(5kPa,15kPa:±0.3%R.C.) |
Hysteresis | ±0.2%R.C.(5kPa,15kPa:±0.3%R.C.) |
Excitation;Recommended | 0.5mA |
Excitation;Maximum | 3mA |
Input Terminal Resistance | 4000~6000Ω |
Output Terminal Resistance | 4000~6000Ω |
Insulation Resistance | 100MΩ or more (DC50V) |
Compensated Temperature Range (Temperature of medium to be measured) |
0~70°C(No condensation or freezing) |
Safe Temperature Range (Temperature of medium to be measured) |
-20~100°C(No condensation or freezing) |
Safe Overload Rating | 200%R.C. |
Ultimate Overload Rating | 300%R.C. |
Temperature Effect on Zero Balance | ±0.2%R.C./10°C(5kPa:±0.5%R.C./10°C) |
Temperature Effect on Load | ±0.2%R.C./10°C(5kPa:±0.5%R.C./10°C) |
Fastening Torque;Recommended | 20N・m |
Fastening Torque;Maximum | 30N・m |
Connection Screw | Selectable: R3/8 and G3/8 |
Pressure Port Material | Aluminum 2017 (Pressure port: Semiconductor) |
Cable | 4-core shielded (oilproof) cable 3m(Standard) φ6mm Waterproof type and Cable pigtail type use a cable in tube of 6.5 mm in diameter. |
Weight | Approx. 100g(Cable not included) |
Accessories | Test report (1 copy) |