Santest GY Series : DC-Q
MELSEC-Q Built-in unit (JCC products)
This unit can be built into PLC MELSEC-Q (Mitsubishi) and stores digital position data (Binary code). The CPU unit can read the data through the buffer memory. One unit can be associated with 1 probe (1 axis) or 2 probes (2 axes).
Specifications
No. of probe | 1 axis or 2 axes |
---|---|
Resolution | Progammable Min.1μm (G1), Min.0.1mm (G2,G3) |
Sampling freq. | 1kHz (STD) (up to stroke 1000mm) |
I/O occupation points | Intelligent, 32 points |
current consumption | 1 axis:0.7A (5VDC), 2 axes:0.9A (5VDC) |
function | external preset, upper and lower limit |
cable length | Max. 200m (G1, G2) Max. 100m(G3) |
working temp. | 0°C-+60°C |
storage temp. | -20°C-+75°C |
Model No.
①No. of probe
1:1 axis
2:2 axes
②Application
blank:FA
H :steel industry
③Probe type
G1:GYSE-R, GYcRS, GYFRS,
GYSE-R-PF, GYKM-RS
G2:GYcRP
G3:GYHR
④Option(1 axis type only)
blank:without option
P :with pulse output
-S01:multi magnet type