Warning: The magic method Gallery_Video::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/gallery-video/video-gallery.php on line 86

Warning: The magic method Hugeit_Slider::__sleep() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 262

Warning: The magic method Hugeit_Slider::__wakeup() must have public visibility in /home3/cp504663/public_html/product/wp-content/plugins/slider-image/slider.php on line 264
Santest GY Series : GYSE-A-PF Probe | TKK Corporation


Santest GY Series : GYSE-A-PF Probe

High performance anglogue output (detachable probe element)

The inside probe element can be detached from the outer housing (standard function for GYSE). Additionally, use of flexible element as an option(page 73) makes the exchange process extremely easy even under small work space. Using two pcs of magnet on the probe as another option, detecting each magnet position or relative distance between the two is possible. With the captive software (GPM), zero and gain adjustment is possible at user side.

Specifications

Non-linearity ≦±0.025%FS TYP
Resolution 16bit(1/65536)
Repeatability ≦±0.001%FS (Min. ±3μm)
Temp. drift ≦±20ppmFS/°C
Position
(STD)
0-10V(output current : Max.5mA, load : Min.2kΩ)
or 4-20mA(load : Max.500Ω)
Velocity
(Option)
±10V(output current : Max.5mA, load : Min.2kΩ)
or 4-20mA(load : Max.500Ω)
Alarm Open drain 50V 0.1A (for magnet missing)
Power supply +24(±2)VDC (70mA)
Sampling freq. Std 1kHz(up to stroke 1000mm)
Operating temp. -20°C-+75°C
Storage temp. -40°C-+75°C
Vibration 15G(20-100Hz)
Shock 100G(2msec)
IP grade IP65

・The above mentioned accuracy applies to sensors with an effective stroke of 300 mm or more.

・Fixing clamps are supplied.
stroke < 600mm:2 pcs
600-1000mm:3 pcs
1001-1200mm:4 pcs
1501-2000mm:5 pcs

Model No.

①Effective stroke
  15-7500mm
②Thread dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)
③Tip dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)
④Associated magnet
  PFU :PFU slide magnet
  M11N :No.11N
  BP :No.5PFT-LG
  M11S :No.11S
  MG□ :other magnet
⑤Cable connection
  CN:connector(STD)
  △G□F:pigtail / cable end : free
  △G□A:pigtail / cable end : with connector for relay
  (□:cable length(m))
  (△:cable type
  S:standard, H:high temp. cable, R:robot cable)
⑥Position output(OUT1)
  AD:0-10V(When magnet moves toward tip, output increase)
  AR:10-0V(When magnet moves toward tip, output decrease)
  BD:4-20mA(When magnet moves toward tip, output increase)
  BR:20-4mA(When magnet moves toward tip, output decrease)
  CD□□:bipolar output(-□V-+□V)
  (for example CD10:-10V-+10V)
  CR□□:bipolar output(+□V–□V)
  (for example CR05:+5V–5V)
  V Z/F:option (specified voltage)
  (for example V1/5:1-5V, V9.5/0.5:9.5-0.5V)
  I Z/F:option (specified current)
  (for example I5.2/20:5.2-20mA, I18/5:18-5mA)
  【Z=output at zero position, F=output at full position】
⑦Option : Analogue output(OUT2)
  ・N:without option(STD)
  ・position output:select from ⑥
  ・Velocity output(Note1)
  VA[ ]:±10V
  WB[ ]:4-20mA
  [ ]:max. velocity(1.00-999 mm/s)
  
  (Note1)
  VA : When magnet stops, output is 0V.
  When moving toward probe tip, +10V.
  WB : When magnet stops, output is 4mA.
  When moving in any direction, 20mA

Dimensions

Probe

magnet

Connection