Non-linearity | ≦±0.05%FS TYP |
---|---|
Resolution | (analogue)≦0.01%FS(with GYHC) (digital)0.1mm(with GYDC-05) |
Repeatability | ≦±0.01%FS |
Temp. drift | ≦±50ppmFS/°C |
Max. Pressure | 35MPa(probe rod) |
Operating temp. | -20°C-+80°C |
Storage temp. | -40°C-+80°C |
Vibration | 6G(40Hz 2mmPP) |
Shock | 100G(2msec) |
IP grade | IP67 |
Cable | Std 1.5m(Option Max.200m) |
・The above mentioned accuracy applies to sensors with an effective stroke of 300 mm or more.
◆associated controler
analogue output:GYHC, GYFC2
digital output:GYDC-05
MelsecQ built-in:DC-Q(JCC)
CC-Link:WAGO I/Osystem750-635
Model No.
①Effective stroke
15mm-5200mm
②Thread dead zone
S:50mm(STD)
□:□mm(option)(specified by customers)
③Tip dead zone
S:70mm/90mm/100mm(STD)
・S (STD length) depends on the selected magnet or float in ⑤.
tip DZ | magnet | float |
---|---|---|
70mm | M2P,MG0,M11 | F25N,F28N |
90mm | F28S,F30S | |
100mm | T142,T162 | F40S,F42S,F50S |
□:□mm(option)(specified by customers)
④Thread/Rod diameter
M :M24xP1.0, rod Φ10(STD)
N :M18xP1.5、, rod Φ10
U :3/4-16UNF-3A, rod Φ10
M8 :M24xP1.0, rod Φ8
N8 :M18xP1.5, rod Φ8
U8 :3/4-16UNF-3A, rod Φ8
M14:M24xP1.0, rod Φ13.8
⑤Associated magnet or float
magnet | float |
---|---|
M2P :No.2P (STD) MG0 :No.Φ M11 :No.11 T142 :No.T14-M2 T162 :No.T16-M2 MG□ :other magnet |
F28S :Φ28 SS316 F30S :Φ30 SS316L F42S :Φ42.5 SS316 F40S :Φ40 SS316(B) F54S :Φ54 SS304 F50S :Φ50 SS316 F28N :RF-A6 plastic F25N :RF-A10 plastic FL□ :other float |
⑥Cable connection
CN:connector(STD)
△G□F:pigtail / cable end : free
△G□A:pigtail / cable end : with connector for relay
△G□FC:pigtail / cable end : with connector for GYFC2/3
□:cable length(m))
△:cable type
S:standard, H:high temp. cable, R:robot cable)
<Water proof option>
WPCN:submersible connector type
WP3G□F:pigtail / cable end : free
WP3G□A:pigtail / cable end : with connector for relay
WP3G□FC:pigtail / cable end : with connector for GYFC2/3
□:cable length(m))
・P73 shows the detailed information
⑦Output
00: depends on external controller
⑧Option(see page 72-74)
blank:without option
SRT:SRT option
H0:probe rod 100°C
H1:probe rod 120°C
H2:probe rod 200°C