Santest GY Series : GYFC2/3 Controller
Analogue output
Specifications
Resolution (position) |
≦0.005%FS (*1) ≦0.01%FS (*2) |
---|---|
Position(OUT1) (OUT2) |
4-20mA(load:Max.500Ω) or inverted output etc |
Velocity (option) |
±10V(Resolution:1%FS) |
Alarm(*3) | Contact 1A 30VDC(*3) |
Power supply | Std:+24VDC±5%(≦350mA) Option:±15VDC、+12VDC(*4) |
Sampling freq. | Std 1kHz(up to stroke 1000mm) |
Temp. drift | ≦±20ppmFS/°C |
Operating temp. | 0°C-+65°C |
Storage temp. | -20°C-+85°C |
・The above mentioned accuracy applies to sensors with an effective stroke of 300 mm or more.
・Zero/Gain adjustments by trimmer are possible. (STD:±3%FS)
(*1)associated probe:GYcRS, GYMR5, GYFRS
(*2)associated probe:GYcRP
(*3)Cable disconnection and magnet drop
(*4)GYcRP probe only
Model No.
①Controller type
2:phenix connector type(STD)
3:terminal type
②Probe
RS:GYcRS
RP:GYcRP
R5:GYMR5
FS:GYFRS
KRS:GYKM-RS
RPH2:GYcRP with H2 option
③Effective stroke(mm)
④Thread dead zone
S:50mm(STD)
□:□mm(option)(specified by customers)
⑤Associated magnet or float
magnet | float |
---|---|
M2P :No.2P (STD) M2PN :No.2PN MG0 :No.Φ M0SM :No.ΦSPM M0LM :No.ΦLPM M3 :No.3 M11 :No.11 M11N :No.11N T142 :No.T14-M2 T144 :No.T14-M4 T162 :No.T16-M2 T163 :No.T16-M3 MG□ :other magnet |
F28S :Φ28 SS316 F30S :Φ30 SS316L F40S :Φ40 SS316(B) F42S :Φ42.5 SS316 F50S :Φ50 SS316 F54S :Φ54 SS304 F25N :RF-A10 plastic F28N :RF-A6 plastic FL□ :other float |
④Thread/Rod diameter
N-FX6:M18xP1.5, flexible rod Φ6
⑤Associated magnet or float
magnet | float |
---|---|
M0SM :No.ΦSPM M0LM :No.ΦLPM M3 :No.3 M2PN :No.2PN (STD) M11N :No.11N T144 :No.T14-M4 T163 :No.T16-M3 MG□ :other magnet |
F30S :Φ30 SS316L F28S :Φ28 SS316 F42S :Φ42.5 SS316 F40S :Φ40 SS316(B) F54S :Φ54 SS304 F50S :Φ50 SS316 F28N :RF-A6 plastic F25N :RF-A10 plastic FL□ :other float |
⑥Position output
OUT1 | OUT2 | |
---|---|---|
AD/AR | 0V-10V | 10V-0V |
AD/BD | 0V-10V | 4mA-20mA |
AR/BR | 10V-0V | 20mA-4mA |
CD05/CR05 | -5V-+5V | +5V–5V |
CD10/CR10 | -10V-+10V | +10V–10V |
⑦Power supply
24S:+24VDC(STD)
15W:±15VDC(option)(GYcRP probe only)
12S:+12VDC(option)(GYcRP probe only)
±15VDC +15V(±5%)≦200mA
-15V(±5%)≦100mA
+12VDC +12V(±3V)≦700mA
⑧Option(blank:No option)
Velocity output(Note1)
V[ ] ([ ]:Max speed(mm/sec))
(Note1)
・You can specify max speed within 3%-300%/sec of effective stroke(mm).
(ex:effective stroke=300mm, 9mm/sec-900mm/sec)
⑨Option
X2:higher sampling freq. (double)
<For higher sampling option>
・probe tip DZ needs extra 30mm
・for example, stroke : 500mm, standard is 1kHz and with X2 option, it is 2kHz.