Santest GY Series : GYKS2 Probe
Compact ・ analogue output type (All-in-one)
Specifications
Non-linearity | ≦±0.025%FS TYP |
---|---|
Resolution | ≦0.01%FS |
Repeatability | ≦±0.01%FS |
Temp. drift | ≦±50ppmFS/°C |
Voltage output | 0-10V or 10-0V (output current:Max.5mA, load:Min.2kΩ) |
Current output | 4-20mA or 20-4mA (load:Max.500Ω) |
Power supply | +24(±2)VDC (less than 100mA) |
Sampling freq. | Std 1kHz(up to stroke 1000mm) |
Operating temp. | 0°C-+65°C |
Storage temp. | -20°C-+65°C |
Vibration | 3G(or 40Hz 1mmPP) |
Shock | 10G(2msec) |
IP grade | IP63-IP65 |
・The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
・Fixing clamps are supplied.
stroke < 600mm : 4 pcs
600-1000mm : 6 pcs
1001-1200mm : 8 pcs
1501-2500mm : 10 pcs
Model No.
①Effective stroke
15mm-2000mm(rod type)
15mm-500mm(both end universal joint type)
15mm-2500mm(other type)
②Magnet
R:rod Φ6(M5 thread)(Standard)
R2:rod Φ6(M5 thread)
R88:rod Φ8(M8 thread)
R85:rod Φ8(M5 thread)
RW88:Both end Universal Joint Type(rod Φ8)
U:Slide magnet
T:Floating magnet(gap 1mm)
TS:Floating magnet(gap 4mm)
TW:Floating magnet(gap 8mm)
U-FX65:Slide magnet
+flexible rod Φ6(M5 thread)
U2-FX88:Slide magnet
+flexible rod Φ8(M8 thread)
③Position output
AD:0-10V(When magnet moves toward tip, output increase)
AR:10-0V(When magnet moves toward tip, output decrease)
BD:4-20mA(When magnet moves toward tip, output increase)
BR:20-4mA(When magnet moves toward tip, output decrease)