Santest GY Series – GYMT Probe / GYMTC Controller
Compact type
Specifications
Non-linearity | ≦±0.05%FS TYP |
---|---|
Resolution | ≦0.01%FS |
Repeatability | ≦±0.01%FS |
Temp. drift | ≦±50ppmFS/°C (probe) ≦±80ppmFS/°C (controller) |
Voltage output | 0-10V or 10-0V (output current:Max.5mA, load:Min.2kΩ) |
Current output | 4-20mA or 20-4mA (load:Max.500Ω) |
Alarm output | not available |
Power supply | ±15VDC (±5%) |
Sampling freq. | Std 1kHz (up to stroke 1000mm) |
Max. Pressure | 35MPa (probe rod) |
Operating temp. | -5°C-+60°C (probe) 0°C-+60°C (controller) |
Storage temp. | -40°C-+80°C |
Vibration | 6G (or 40Hz 2mmPP) |
Shock | 50G (2msec) |
IP grade | IP67 (probe) |
Cable | Std 1.5m (Option Max.10m) |
*The above mentioned accuracy applies to sensors with an effective
stroke of 300mm or more.
*Zero/Gain adjustment by trimmer of controller are possible, std within ±3%FS.
Model No.
①Effective stroke
15mm-2000mm
②Thread dead zone
S:50mm (STD)
□:□mm(option)(specified by customers)
③Tip dead zone
S:70mm/90mm/100mm(STD)
・S (STD length) depends on the selected magnet or float in ⑤.
tip DZ | magnet | float |
---|---|---|
70mm | M2P, M0, M11 | F25N, F28N |
90mm | F28S, F30S | |
100mm | T142, T162 | F40S, F42S, F50S |
□:□mm(option)(specified by customers)
④Thread/Rod diameter
J8 :M20xP1.0, rod Φ8(STD)
L8 :M16xP2.0, rod Φ8
E8 :M20xP1.5, rod Φ8
N :M18xP1.5, rod Φ10
U :3/4-16UNF-3A, rod Φ10
K6 :M16xP1.5, rod Φ6
⑤Associated magnet or float
magnet | float |
---|---|
M2P :No.2P (STD) MG0 :No.Φ M11 :No.11 T142 :No.T14-M2 T162 :No.T16-M2 MG□ :other magnet |
F28S :Φ28 SS316 F30S :Φ30 SS316L F40S :Φ40 SS316(B) F42S :Φ42.5 SS316 F50S :Φ50 SS316 F54S :Φ54 SS304 F25N :RF-A10 plastic F28N :RF-A6 plastic FL□ :other float |
⑥Cable connection
G□F:pigtail / cable end : free
G□A:pigtail / cable end : with connector for relay
(□:cable length(m))
CN:connector(option)
・Please use the cable as specified on order.
・The cable extend and cut needs the readjustment in the factory.
・The terminal stand and the connector etc. can be used to connect cable.
・For ordering extend cable, please see page 77.
⑦Position output
AD:0-10V(When magnet moves toward tip, output increase)
AR:10-0V(When magnet moves toward tip, output decrease)
BD:4-20mA(When magnet moves toward tip, output increase)
BR:20-4mA(When magnet moves toward tip, output decrease)
CD□□:bipolar output(-□V-+□V)
(for example CD10:-10V-+10V)
CR□□:bipolar output(+□V–□V)
(for example CR05:+5V–5V)
⑧Power supply
15W:±15VDC(STD)
+15V±5% (≦100mA)
-15V±5% (≦50mA)
24S:+24VDC(option for retrofit)
12S:+12VDC(option)
・In case of selecting 24S, we would recommed
GYMS/GYMSC series(P18,P19).