Santest GY Series - GYPE2K Probe / GYMSC Controller | TKK Corporation


Santest GY Series – GYPE2K Probe / GYMSC Controller

Probe rod Φ4

The GYPE2K probe is a sensor characterized in a fine rod and a small head. A fine rod (outside diameter Φ4) and a small head expand the design flexibility of the equipment.
Standard magnet and float can be used.
With the GYMSC controller, it outputs analogue signal of 0-10V or 4-20mA.

Specifications

Non-linearity ≦±0.5%FS TYP
Resolution ≦0.01%FS
Repeatability ≦±0.01%FS
Repeatability ≦±0.01%FS/°C (probe)
≦±0.01%FS/°C (cotroller)
Voltage output 0-10V or 10-0V
(output current:Max.5mA, load:Min.2kΩ)
Current output 4-20mA or 20-4mA
(load:Max.500Ω)
Alarm output not available
Power supply +24(±2)VDC (100mA)
Sampling freq. approx 1kHz sampling (Note1)
Max. Pressure 18MPa(probe rod, static for 10 min.)
Operating temp. -20°C-+80°C (probe)
0°C-+60°C (controller)
Storage temp. -40°C-+80°C
Vibration 3G (or 40Hz 1mmPP)
Shock 20G (2msec)
IP grade IP64 (probe)
Cable Std 1.5m (Option Max.5m)

・The above mentioned accuracy applies to sensors with an effective stroke of 100mm or more.
・Zero/Gain adjustment by trimmer of controller are possible, std within ±3%FS.
(Note1) liquid level application:approx 100Hz sampling

Model No.

①Effective stroke
  50mm-250mm
②Thread dead zone
  S:35mm(No.Φ magnet)
    28mm(Ti float)
  □:□mm(option)(specified by customers)
③Tip dead zone
  S:30mm(No.Φ magnet)
    42mm(Ti float)
  □:□mm(option)(specified by customers)
④Thread/Rod diameter
  Y4 :M18xP1.0, rod Φ4(STD)
⑤Associated magnet or float

magnet float
MG0 :No.Φ(STD) FL21 :Ti

⑥Cable connection
  G□F:pigtail / cable end : free
  G□A:pigtail / cable end : with connector for relay
     (□:cable length(m))
  Please use the cable as specified though it is possible to extend to Max.
  5m in case so specify in advance. (The cable cannot beextended, nor cut.)
  The terminal stand or connector etc. can be used to arrange cable length.
⑦Position output
  AD:0-10V(When magnet moves toward tip, output increase)
  AR:10-0V(When magnet moves toward tip, output decrease)
  BD:4-20mA(When magnet moves toward tip, output increase)
  BR:20-4mA(When magnet moves toward tip, output decrease)
  CD□□:bipolar output(-□V-+□V)
      (for example CD10:-10V-+10V)
  CR□□:bipolar output(+□V–□V)
      (for example CR05:+5V–5V)

Dimensions