Santest GY Series - GYPM Probe / GYPMC Controller | TKK Corporation


Santest GY Series – GYPM Probe / GYPMC Controller

Dead zone 30mm (thread side)

The sensor head of GYPM probe is more compact. By new design of probe head, screw side dead zone has been shortened to 30mm (Standard). As to tip dead zone, making short to 40mm is possible by option (standard: 70mm). Cable out direction is radial.

GYPM probe is used in combination with the GYPMC controller, which provides analogue output, 0-10V or 4-20mA, and can also be used in combination with GYHC or GYDC-05 controller, which provides velocity output or digital output. (refer P.42, P.46)

Specifications

Non-linearity ≦±0.05%FS TYP
Resolution ≦0.01%FS
Repeatability ≦±0.01%FS
Temp. drift ≦±70ppmFS/°C (probe)
≦±50ppmFS/°C (controller)
Voltage output 0-10V or 10-0V
(output current:Max.5mA, load:Min.2kΩ)
Current output 4-20mA or 20-4mA
(load:Max.500Ω)
Alarm output not available
Power supply +24(±2)VDC (100mA)
Sampling freq. Std 1kHz (up to stroke 1000mm)
Max. Pressure 35MPa (probe rod)
Operating temp. -5°C-+60°C (probe)
0°C-+60°C (controller)
Storage temp. -40°C-+80°C
Vibration 6G (or 40Hz 2mmPP)
Shock 20G (2msec)
IP grade IP64 (probe)
Cable Std 1.5m (Option Max.100m)

・The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
・Zero/Gain adjustment by trimmer of controller are possible, std within ±3%FS.

Model No.

①Effective stroke
  15-1000mm
②Thread dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)
③Tip dead zone
  S:70mm/90mm/100mm(STD)
  ・S (STD length) depends on the selected magnet or float in ⑤.

tip DZ magnet float
70mm M2PN, M0SM, M0LM,
M3, M11N
F25N, F28N
90mm F28S, F30S
100mm T144, T163 F40S, F42S, F50S

□:□mm(option)(specified by customers)

④Thread/Rod diameter
  N8 :M18xP1.5, rod Φ8(STD)
⑤Associated magnet or float

magnet float
M2PN :No.2PN (STD)
M0SM :No.ΦSPM
M0LM :No.ΦLPM
M3 :No.3
M11N :No.11N
T144 :No.T14-M4
T163 :No.T16-M3
MG□ :other magnet
F28S :Φ28 SS316
F30S :Φ30 SS316L
F40S :Φ40 SS316(B)
F42S :Φ42.5 SS316
F50S :Φ50 SS316
F54S :Φ54 SS304
F25N :RF-A10 plastic
F28N :RF-A6 plastic
FL□ :other float

⑥Cable connection
  G□F:pigtail / cable end : free
  G□A:pigtail / cable end : with connector for relay
     (□:cable length(m))
⑦Position output
  AD:0-10V(When magnet moves toward tip, output increase)
  AR:10-0V(When magnet moves toward tip, output decrease)
  BD:4-20mA(When magnet moves toward tip, output increase)
  BR:20-4mA(When magnet moves toward tip, output decrease)
  CD□□:bipolar output(-□V-+□V)
      (for example CD10:-10V-+10V)
  CR□□:bipolar output(+□V–□V)
      (for example CR05:+5V–5V)

Dimensions