Santest GY Series : GYSE-A-FX6 Probe
Flexible rod type analogue output
Specifications
Non-linearity | ≦±0.025%FS TYP |
---|---|
Resolution | 16bit(1/65536) |
Repeatability | ≦±0.001%FS (Min. ±3μm) |
Position (STD) |
0-10V(output current : Max.5mA, load : Min.2kΩ) or 4-20mA(load : Max.500Ω) |
Velocity (Option) |
±10V or 4-20mA Resolution:16bit(1/65536) |
Alarm | Open drain 50V 0.1A (for lost magnet) |
Power supply | +24(±2)VDC (70mA) |
Sampling freq. | Std 1kHz(up to stroke 1000mm) |
Max. Pressure | 5MPa(probe rod) |
Operating temp. | 0°C-+65°C |
Storage temp. | -20°C-+65°C |
Vibration | 3G(or 40Hz 1mmPP) |
Shock | 10G(2msec) |
IP grade | IP67 (probe head) |
・The above mentioned accuracy applies to sensors with an effective stroke of 300 mm or more.
Model No.
①Effective stroke
15-7500mm
②Thread dead zone
S:50mm(STD)
□:□mm(option)(specified by customers)
③Tip dead zone
S:70mm/90mm/100mm(STD)
・S (STD length) depends on the selected magnet or float in ⑤.
tip DZ | magnet | float |
---|---|---|
70mm | M2PN, M0SM, M0LM, M3, M11N |
F25N, F28N |
90mm | F28S, F30S | |
100mm | T144, T163 | F40S, F42S, F50S |
□:□mm(option)(specified by customers)
④Thread/Rod diameter
N-FX6:M18xP1.5, flexible rod Φ6
⑤Associated magnet or float
magnet | float |
---|---|
M0SM :No.ΦSPM M0LM :No.ΦLPM M3 :No.3 M2PN :No.2PN (STD) M11N :No.11N T144 :No.T14-M4 T163 :No.T16-M3 MG□ :other magnet |
F30S :Φ30 SS316L F28S :Φ28 SS316 F42S :Φ42.5 SS316 F40S :Φ40 SS316(B) F54S :Φ54 SS304 F50S :Φ50 SS316 F28N :RF-A6 plastic F25N :RF-A10 plastic FL□ :other float |
⑥Cable connection
CN:connector(STD)
△G□F:pigtail / cable end : free
△G□A:pigtail / cable end : with connector for relay
(□:cable length(m))
(△:cable type
S:standard, H:high temp. cable, R:robot cable)
⑦Position output(OUT1)
AD:0-10V(When magnet moves toward tip, output increase)
AR:10-0V(When magnet moves toward tip, output decrease)
BD:4-20mA(When magnet moves toward tip, output increase)
BR:20-4mA(When magnet moves toward tip, output decrease)
CD□□:bipolar output(-□V-+□V)
(for example CD10:-10V-+10V)
CR□□:bipolar output(+□V–□V)
(for example CR05:+5V–5V)
V Z/F:option (specified voltage)
(for example V1/5:1-5V, V9.5/0.5:9.5-0.5V)
I Z/F:option (specified current)
(for example I5.2/20:5.2-20mA, I18/5:18-5mA)
Ordering loose connector only.
⑧Option : Analogue output(OUT2)
・N:without option(STD)
・position output:select from ⑦
・Velocity output(Note1)
VA[ ]:±10V
WB[ ]:4-20mA
[ ]:max. velocity(1.00-999 mm/s)
(Note1)
VA : When magnet stops, output is 0V.
When moving toward probe tip, +10V.
WB : When magnet stops, output is 4mA.
When moving in any direction, 20mA.
S:straight
L:L-shaped
For GYSE connector, we recommend to purchase our cable with connector since a special clamp tool is necessary to mount the connector at cable end.
CN-LM-0-□
【Z=output at zero position, F=output at full position】