Santest GY Series : GYSE-P-PF Probe
Profibus DP interface (detachable probe element)
Profibus interface type. Setting parameters (resolution, output direction) through profibus is possible. Detecting up to 32 pcs of magnets on one probe is possible. GSD file is available on SANTEST web site.
Specifications
Non-linearity | ≦±0.025%FS TYP |
---|---|
Resolution | Min.1μm(set by Profibus Configurator) |
Repeatability | ≦±0.001%FS (Min. ±3μm) |
Temp. drift | ≦±15ppmFS/°C |
Output | Profibus DPV0 |
Power supply | +24(±2)VDC (70mA) |
Sampling freq. | Stroke -800mm : 2000Hz -2200mm : 1000Hz -5000mm : 500Hz 5001mm- : 250Hz |
Operating temp. | -20°C-+75°C |
Storage temp. | -40°C-+75°C |
Vibration | 15G (20-100Hz) |
Shock | 100G(2msec) |
IP grade | IP65 |
・The above mentioned accuracy applies to sensors with an effective stroke of 300 mm or more.
・Fixing clamps are supplied.
stroke < 600mm:2 pcs
600-1000mm:3 pcs
1001-1200mm:4 pcs
1501-2000mm:5 pcs
Model No.
①Effective stroke
15-7500mm
②Thread dead zone
S:50mm(STD)
□:□mm(option)(specified by customers)
③Tip dead zone
S:50mm(STD)
□:□mm(option)(specified by customers)
④Associated magnet
PFU :PFU slide magnet
M11N :No.11N
BP :No.5PFT-LG
M11S :No.11S
MG□ :other magnet
⑤Cable connection
CN:connector(STD)
⑥Option
blank:without option
L:linearization option(≦0.006%FS TYP)